Imaging of the liver with helical CT: A survey of scanning techniques

被引:22
作者
Silverman, PM
Kohan, L
Ducic, I
Javadi, S
Meyer, C
Sharma, N
Cooper, CC
Zeman, RK
机构
[1] Georgetown Univ Hosp, Dept Radiol, Washington, DC 20007 USA
[2] Georgetown Univ Hosp, Dept Surg, Washington, DC 20007 USA
[3] Georgetown Univ, Coll Arts & Sci, Washington, DC 20007 USA
[4] Georgetown Univ, Sch Med, Washington, DC 20007 USA
关键词
D O I
10.2214/ajr.170.1.9423622
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. We conducted a survey of the members of the Society of Computed Body Tomography/Magnetic Resonance to assess current techniques in liver imaging using helical CT. MATERIALS AND METHODS. The survey, which was designed to update earlier surveys from 1987 and 1993, included a questionnaire distributed to 77 members of the Society of Computed Body Tomography/Magnetic Resonance. RESULTS. Forty-nine members responded, representing 28 institutions, In 1993, 19% (5/26) of institutions used helical scanners, compared with 82% (23/28) in 1996. The group of institutions with helical CT served as the focus of this survey, In 1993, 58% of institutions used 1-cm collimation; in 1996, 78% (18/23) used thinner, 7- to 8-mm collimation. In 1987, 41% used power injectors compared with 85% in 1993 and 100% in 1996. In 1996, monophasic injections were used by 96% (22/23) of institutions. In 1993, most institutions used a contrast material injection rate of 1.5-2.0 ml/sec; in 1996, most used a 2.5-3.0 ml/sec injection rate, In 1993, 96% of institutions used 125-150 ml of contrast material; in 1996, 57% (13/23) of institutions used 125-150 ml and 30% of institutions used less than 125 ml of contrast material. A delay time of 21-45 sec was used by 83% of institutions in 1993, whereas in 1996, 83% (19/23) of institutions used a longer delay time of 50-80 sec, In 1996, 13% of institutions used an individual scan delay technology and all institutions performed multiphasic scanning of hypervascular lesions. CONCLUSION, The availability of helical CT has changed radiologists' approach to liver imaging. The greatest effects of which are a more widespread use of power injectors, longer delay times, thinner collimation, increased contrast material injection rates, decreased contrast material volumes, and multiphasic scanning.
引用
收藏
页码:149 / 152
页数:4
相关论文
共 19 条
[1]   UNDERSTANDING AND OPTIMIZING USE OF CONTRAST MATERIAL FOR CT OF THE LIVER [J].
BARON, RL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (02) :323-331
[2]  
BERLAND LL, 1995, RADIOLOGY, V195, P1
[3]  
BIMBAUM B, 1995, AJR, V165, P853
[4]   SPIRAL CT OF THE LIVER [J].
BLUEMKE, DA ;
FISHMAN, EK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (04) :787-792
[5]   Extravasation of radiographic contrast material: Recognition, prevention, and treatment [J].
Cohan, RH ;
Ellis, JH ;
Garner, WL .
RADIOLOGY, 1996, 200 (03) :593-604
[6]   SPIRAL CT OF THE THORAX WITH REDUCED VOLUME OF CONTRAST MATERIAL - A COMPARATIVE-STUDY [J].
COSTELLO, P ;
DUPUY, DE ;
ECKER, CP ;
TELLO, R .
RADIOLOGY, 1992, 183 (03) :663-666
[7]   INVESTIGATION OF CONTRAST ENHANCEMENT IN CT OF THE LIVER - THE NEED FOR IMPROVED METHODS [J].
DODD, GD ;
BARON, RL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) :643-645
[8]   HELICAL CT - CLINICAL-PERFORMANCE AND IMAGING STRATEGIES [J].
FOLEY, WD ;
ONESON, SR .
RADIOGRAPHICS, 1994, 14 (04) :894-904
[9]   DYNAMIC HEPATIC CT SCANNING [J].
FOLEY, WD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (02) :272-274
[10]   Timing of parenchymal enhancement on dual-phase dynamic helical CT of the liver: How long does the hepatic arterial phase predominate? [J].
Frederick, MG ;
McElaney, BL ;
Singer, A ;
Park, KS ;
Paulson, EK ;
McGee, SG ;
Nelson, RC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (06) :1305-1310