Effect of the Confidential Enquiries into Maternal Deaths on the use of Syntocinon® at Caesarean section in the UK

被引:47
作者
Bolton, TJ [1 ]
Randall, K [1 ]
Yentis, SM [1 ]
机构
[1] Chelsea & Westminster Hosp, Magill Dept Anaesthesia Intens Care & Pain Manage, London SW10 9NH, England
关键词
oxytocics; syntocinon; medical audit; maternal mortality; caesarean section;
D O I
10.1046/j.1365-2044.2003.30435.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The recommended dose of Syntocinon used for uterine contraction at Caesarean section is 5 units intravenously, given slowly. We conducted a survey of the use of Syntocinon at Caesarean section among 240 lead obstetric anaesthetists in the UK in 2001 and found that 155 (87%) of the 179 (75%) respondents gave 10 units, 77 of them (50%) by rapid bolus. The risks of Syntocinon, especially given by rapid injection, were highlighted in the report of the Confidential Enquiries into Maternal Deaths in the UK (1997-99), which was published at the end of 2001, and so the survey was repeated in 2002. Of the 256 forms sent, 198 completed replies were returned (77%); these indicated a dramatic change of practice: only 30 (15%) now gave 10 units and only 7 of these (23%) by a rapid injection. One hundred and sixty-seven respondents to the second survey (84%) stated they had changed their practice and 159 of these (95%) gave the Confidential Enquiries report as the main reason for change. These results highlight the importance of the Confidential Enquiries as a means of improving practice.
引用
收藏
页码:277 / 279
页数:3
相关论文
共 7 条
[1]  
[Anonymous], 2001, WHY MOTH DIE REP CON
[2]  
*BRIT MED ASS, 2002, BRIT NAT FORM
[3]  
Hibbard B, 1994, Health Trends, V26, P26
[4]   The confidential enquiries into maternal deaths 1997-1999: what can we learn? [J].
May, A .
INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2002, 11 (03) :153-155
[5]   Oxytocin during Caesarean section [J].
Spence, A .
ANAESTHESIA, 2002, 57 (07) :722-723
[6]  
WEIS FR, 1975, OBSTET GYNECOL, V46, P211
[7]  
Yentis SM, 1998, ANAESTHESIA, V53, P606