Cross-sectional characteristics of the masseter muscle: an ultrasonographic study

被引:24
作者
Bertram, S
Brandlmaier, I
Rudisch, A
Bodner, G
Emshoff, R
机构
[1] Univ Innsbruck, Dept Oral & Maxillofacial Surg, A-6020 Innsbruck, Austria
[2] Univ Innsbruck, Dept Radiol, A-6020 Innsbruck, Austria
关键词
masseter muscle; ultrasonography;
D O I
10.1054/ijom.2002.0259
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
Cross-sections of the masseter muscle may now be measured non-invasively using ultrasonography. The purpose of the present study was to determine (1) whether the scanning level may affect cross-sectional measurements and (2) whether measurements made at identical levels may be reproducible. The study included 42 asymptomatic volunteers. Unilateral ultrasonographic investigation was performed with a linear (B-scan) 7.5 Mhz small-part transducer to register cross-sections of the masseter muscle on five different levels. Scans were made on the relaxed and contracted muscle. Measurements were made in two sessions with a time interval of at least 5 min. Statistical analysis consisted of univariate analysis of variance for repeated measurements. Data were analysed for reproducibility by using the method error and measurement error. For the ultrsonographic measurements the main effects of the variables 'session' (P=0.0001), 'level' (P=0.0001), and 'condition' (P=0.0001) were significant. Analysis of simple session-within-level effects revealed a significant difference between the repeated measurements for the most upper level (P=0.022), the upper level (P=0.012), and the most lower level (P=0.0001) of the relaxed muscle. An additional significant effect was found for the most lower level of the contracted muscle (P=0.015). Cross-sections evaluated at the middle (method error=0.31 mm; measurement error=2.0%) and lower level (method error=0.32 mm; measurement error=2.4%) of the contracted muscle were the most reproducible. The conclusion is that ultrasonography is a reproducible method for measuring cross-sections at the middle and lower level of the contracted masseter muscle.
引用
收藏
页码:64 / 68
页数:5
相关论文
共 26 条
[1]
[Anonymous], 2000, Foundations of clinical research: applications to practice
[2]
BAKKE M, 1992, SCAND J DENT RES, V100, P164
[3]
Ultrasonographic assessment of the swelling of the human masseter muscle after static and dynamic activity [J].
Bakke, M ;
Thomsen, CE ;
Vilmann, A ;
Soneda, K ;
Farella, M ;
Moller, E .
ARCHIVES OF ORAL BIOLOGY, 1996, 41 (02) :133-140
[4]
Masseter muscle volume measured using ultrasonography and its relationship with facial morphology [J].
Benington, PCM ;
Gardener, JE ;
Hunt, NP .
EUROPEAN JOURNAL OF ORTHODONTICS, 1999, 21 (06) :659-670
[5]
ULTRASONOGRAPHY OF MASSETER MUSCLE SIZE IN NORMAL YOUNG-ADULTS [J].
CLOSE, PJ ;
STOKES, MJ ;
LESTRANGE, PR ;
ROWELL, J .
JOURNAL OF ORAL REHABILITATION, 1995, 22 (02) :129-134
[6]
THE ULTRASONIC VALUE OF LOCAL MUSCLE HYPERTROPHY IN PATIENTS WITH TEMPOROMANDIBULAR-JOINT DISORDERS [J].
EMSHOFF, R ;
BERTRAM, S .
JOURNAL OF PROSTHETIC DENTISTRY, 1995, 73 (04) :373-376
[7]
The diagnostic value of ultrasonography to determine the temporomandibular joint disk position [J].
Emshoff, R ;
Bertram, S ;
Rudisch, A ;
Gassner, R .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1997, 84 (06) :688-696
[8]
Topographic variations in anatomical structures of the anterior neck of children - An ultrasonographic study [J].
Emshoff, R ;
Bertram, S ;
Kreczy, A .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1999, 87 (04) :429-436
[9]
The short-term effect of stabilization-type splints on local cross-sectional dimensions of muscles of the head and neck [J].
Emshoff, R ;
Bertram, S .
JOURNAL OF PROSTHETIC DENTISTRY, 1998, 80 (04) :457-461
[10]
The combined use of US and MR imaging for the diagnosis of masses in the parotid region [J].
Goto, TK ;
Yoshiura, K ;
Nakayama, E ;
Yuasa, K ;
Tabata, O ;
Nakano, T ;
Kawazu, T ;
Tanaka, T ;
Miwa, K ;
Shimizu, M ;
Chikui, T ;
Okamura, K ;
Kanda, S .
ACTA RADIOLOGICA, 2001, 42 (01) :88-95