Assessment of left ventricular function by different speckle-tracking software

被引:110
作者
Manovel, Ana [1 ]
Dawson, David [1 ]
Smith, Benjamin [1 ]
Nihoyannopoulos, Petros [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Cardiol, Hammersmith Hosp, NHLI, London W12 0NN, England
来源
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY | 2010年 / 11卷 / 05期
关键词
Left ventricular function; Speckle tracking; Myocardial strain; HYPERTROPHIC CARDIOMYOPATHY; 2-DIMENSIONAL SPECKLE; PIXEL TRACKING; RADIAL STRAIN; VELOCITY; DYSFUNCTION; AGREEMENT;
D O I
10.1093/ejechocard/jep226
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Two-dimensional (2D) speckle echocardiography enables objective assessment of left ventricular function through the analysis of myocardial strain, which can be measured by different speckle-tracking software. The aim of this study was to compare two different commercially available cardiac ultrasound systems and their manufacturer-specific speckle-tacking software for the quantification of global myocardial strain in a healthy population. Twenty-eight healthy subjects (age: 38 +/- 12, 64% males) underwent two 2D echocardiograms within the same day using different cardiac ultrasound systems: Vivid 7 (GE Ultrasound, Horten, Norway) and Artida 4D (Toshiba Medical Systems). Standard apical and short-axis views of the left ventricle were obtained in each subject with a frame-rate range of 60 +/- 20 frames/s. Global longitudinal, radial, and circumferential strain values were analysed using their respective speckle-tracking software for Vivid (2D-strain EchoPac PC v.7.0.1, GE Healthcare, Horten, Norway) and Toshiba systems (2D Wall Motion Tracking, Toshiba Medical Systems). Global strain values were estimated from the average of regional left ventricular strain values. Agreement between the two systems and software was assessed by Bland-Altman method. Mean left ventricular ejection fraction was 59 +/- 7%. Global longitudinal, radial, and circumferential strain values were, respectively, -21.95 +/- 1.8, 46.97 +/- 5.5, and -23.18 +/- 3.3% when using 2D-strain EchoPac and -22.28 +/- 2.1, 40.74 +/- 4.3, and -27.17 +/- 4.7% when 2D Wall Motion Tracking was used (P = NS). Limits of agreement between both speckle-tracking software were narrower for global longitudinal strain (-2.25 to 3.65) than for radial and circumferential strain (-2.23 to 12.44 and -1.36 to 10.54, respectively). Two commercially available speckle-tracking software appear to be comparable when quantifying left ventricular function in a healthy population. Global longitudinal strain is a more robust parameter than radial and circumferential strain for the assessment of myocardial function when different cardiac ultrasound systems are used for analysis.
引用
收藏
页码:417 / 421
页数:5
相关论文
共 18 条
  • [1] Advanced speckle tracking echocardiography allowing a three-myocardial layer-specific analysis of deformation parameters
    Adamu, Umar
    Schmitz, Fabian
    Becker, Michael
    Kelm, Malte
    Hoffmann, Rainer
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (02): : 303 - 308
  • [2] Analysis of myocardial deformation based on pixel tracking in two dimensional echocardiographic images enables quantitative assessment of regional left ventricular function
    Becker, M.
    Bilke, E.
    Kuehl, H.
    Katoh, M.
    Kramann, R.
    Franke, A.
    Buecker, A.
    Hanrath, P.
    Hoffmann, R.
    [J]. HEART, 2006, 92 (08) : 1102 - 1108
  • [3] Analysis of myocardial deformation based on ultrasonic pixel tracking to determine transmurality in chronic myocardial infarction
    Becker, Michael
    Hoffmann, Rainer
    Kuehl, Harald P.
    Grawe, Helena
    Katoh, Markus
    Kramann, Rafael
    Buecker, Arno
    Hanrath, Peter
    Heussen, Nicole
    [J]. EUROPEAN HEART JOURNAL, 2006, 27 (21) : 2560 - 2566
  • [4] Velocity and deformation imaging for the assessment of myocardial dysfunction
    Bijnens, Bart H.
    Cikes, Maja
    Claus, Piet
    Sutherland, George R.
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (02): : 216 - 226
  • [5] A NOTE ON THE USE OF THE INTRACLASS CORRELATION-COEFFICIENT IN THE EVALUATION OF AGREEMENT BETWEEN 2 METHODS OF MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 1990, 20 (05) : 337 - 340
  • [6] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [7] Systolic myocardial mechanics in hypertrophic cardiomyopathy: Novel concepts and implications for clinical status
    Carasso, Shemy
    Yang, Hua
    Woo, Anna
    Vannan, Mani A.
    Jamorski, Michal
    Wigle, Douglas
    Rakowski, Harry
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (06) : 675 - 683
  • [8] Comparison of two-dimensional speckle and tissue velocity based strain and validation with harmonic phase magnetic resonance imaging
    Cho, Goo-Yeong
    Chan, Jonathan
    Leano, Rodel
    Strudwick, Mark
    Marwick, Thomas H.
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (11) : 1661 - 1666
  • [9] Longitudinal 2D strain at rest predicts the presence of left main and three vessel coronary artery disease in patients without regional wall motion abnormality
    Choi, Jin-Oh
    Cho, Sung Won
    Bin Song, Young
    Cho, Soo Jin
    Song, Bong Gun
    Lee, Sang-Chol
    Park, Seung Woo
    [J]. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (05): : 695 - 701
  • [10] Determination of transmural, endocardial, and epicardial radial strain and strain rate from phase contrast MR velocity data
    Delfino, Jana G.
    Fornwalt, Brandon K.
    Eisner, Robert L.
    Leon, Angel R.
    Oshinski, John N.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (03) : 522 - 528