Due to the wide application of composite insulators in the power industry, the insulator performance is challenged by various environments. To determine the flashover performance of rime-iced composite insulator, laboratory investigation was carried out in an artificial climate chamber to simulate different rime-ice morphology on the insulator surface. The configuration and characteristics of the rime-ice were demonstrated to establish the relationship between the rime-ice parameters and the flashover performance. In accordance with the discharge phenomena, the transition of leakage current (LC) until the flashover was analyzed by using a recurrent plot approach. After extracting the high frequency components by using a wavelet transform technique, the LC just before the flashover was extended to m dimensional phase space based on a phase space reconstructed method. The recurrent plot was obtained to reveal the non-linear characteristics of LC for identifying the dynamic behaviors on the insulator surface. It is shown that the propagation and properties of the discharges can be graphically projected on the topological structure of recurrent plot as a function of the rime-ice parameters. The process and underlying mechanism of flashover performance of rime-iced composite insulator can be visually reflected by the recurrent plot and the quantitative indicators of LC.
引用
收藏
页码:465 / 472
页数:8
相关论文
共 23 条
[1]
Chand N, 2002, INDIAN J ENG MATER S, V9, P299
[2]
Recunrence plot analysis of discharge currents in tracking tests of gamma-ray irradiation polymers [J].
Du, B. X. ;
Dong, D. S. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2008, 15 (04) :974-981
[3]
Recurrent Plot Analysis of Leakage Current for Monitoring Outdoor Insulator Performance [J].
Du, B. X. ;
Liu, Yong ;
Liu, H. J. ;
Yang, Y. J. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2009, 16 (01) :139-146
[4]
Insulator icing test methods, selection criteria and mitigation alternatives [J].
Farzaneh, M. ;
Chisholm, W. A. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (06) :1462-1473
[5]
FARZANEH M, 1993, IEEE 1993 ANNUAL REPORT, P499, DOI 10.1109/CEIDP.1993.378923
[6]
Leakage current patterns on contaminated polymeric surfaces [J].
Fernando, MARM ;
Gubanski, SM .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1999, 6 (05) :688-694
[7]
Surface resistance measurements on nonceramic insulators [J].
Gorur, RS ;
Schneider, HM ;
Cartwright, J ;
Beausajour, Y ;
Kondo, K ;
Gubanski, S ;
Hartings, R ;
Shah, M ;
McBride, J ;
de Tourreil, C ;
Szilagyi, Z .
IEEE TRANSACTIONS ON POWER DELIVERY, 2001, 16 (04) :801-805
[8]
Diagnostic methods for outdoor polymeric insulators [J].
Gubanski, S. M. ;
Dernfalk, A. ;
Andersson, J. ;
Hillborg, H. .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (05) :1065-1080
[9]
Modern outdoor insulation - Concerns and challenges [J].
Gubanski, SM .
IEEE ELECTRICAL INSULATION MAGAZINE, 2005, 21 (06) :5-11
[10]
HARA M, 1979, IEEE T POWER AP SYST, V98, P849, DOI 10.1109/TPAS.1979.319297