Stenting of "unprotected" left main coronary artery stenoses:: early and late results

被引:20
作者
Laruelle, CJJ [1 ]
Brueren, GBR [1 ]
Ernst, SMPG [1 ]
Bal, ET [1 ]
Mast, GE [1 ]
Suttorp, MJ [1 ]
de la Rivière, AB [1 ]
Plokker, THW [1 ]
机构
[1] St Antonius Hosp, Dept Intervent Cardiol & Cardiothorac Surg, NL-3435 Nieuwegein, Netherlands
关键词
stent; left main coronary artery disease;
D O I
10.1136/hrt.79.2.148
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective-To assess short and long term efficacy of coronary stent implantation for unprotected left main coronary artery stenosis. Design - Retrospective follow up study. Setting - Tertiary referral centre for interventional cardiology and cardiac surgery. Patients - Eighteen consecutive patients (12 men; age 70.8 years) between May 1993 and July 1996. Ten patients presented with stable angina and underwent the procedure electively, eight patients presented either with unstable angina or myocardial infarction and underwent the procedure in emergency Intervention - Johnson and Johnson Palmaz-Schatz stents were used in 16 patients, and a Microstent and a Gianturco-Roubin in one patient each. An intra-aortic balloon pump was prophylactively used for two patients in the elective group. In the acute group, Six required an intra-aortic balloon pump. Main outcome measures - Procedural success rate and major adverse cardiac events. Results - Successful stent implantation was achieved in all patients. In the elective group, no major adverse cardiac event occurred during the procedure, but one patient had to undergo repeated angioplasty before discharge. All patients of of the elective group were discharged alive and there has been one non-cardiac death during a follow up of (mean (SD)) 10 (4) months. In the emergency group, one patient died during the procedure, one patient developed a non Q-wave myocardial infarction, one patient underwent emergency coronary bypass surgery, while another patient died suddenly before hospital discharge. Six patients of the emergency group were discharged alive and there has been one non-cardiac death during a follow up of 7 (4) months. Conclusions - Elective stent implantation for unprotected left main coronary artery stenosis is safe and effective in selected stable patients. Urgent stent implantation, however, cannot be considered as a definitive procedure in emergency situation.
引用
收藏
页码:148 / 152
页数:5
相关论文
共 14 条
[1]   EFFECT OF CORONARY-BYPASS SURGERY ON SURVIVAL PATTERNS IN SUBSETS OF PATIENTS WITH LEFT MAIN CORONARY-ARTERY DISEASE - REPORT OF THE COLLABORATIVE STUDY IN CORONARY-ARTERY SURGERY (CASS) [J].
CHAITMAN, BR ;
FISHER, LD ;
BOURASSA, MG ;
DAVIS, K ;
ROGERS, WJ ;
MAYNARD, C ;
TYRAS, DH ;
BERGER, RL ;
JUDKINS, MP ;
RINGQVIST, I ;
MOCK, MB ;
KILLIP, T .
AMERICAN JOURNAL OF CARDIOLOGY, 1981, 48 (04) :765-777
[2]   PROGNOSTIC SPECTRUM OF LEFT MAIN STENOSIS [J].
CONLEY, MJ ;
ELY, RL ;
KISSLO, J ;
LEE, KL ;
MCNEER, JF ;
ROSATI, RA .
CIRCULATION, 1978, 57 (05) :947-952
[3]  
DION R, 1990, J THORAC CARDIOV SUR, V99, P241
[4]   RESULTS OF PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY OF THE LEFT MAIN CORONARY-ARTERY [J].
ELDAR, M ;
SCHULHOFF, N ;
HERZ, I ;
FRANKEL, R ;
FELD, H ;
SHANI, J .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (02) :255-256
[5]  
FAJADET J, 1996, J AM COLL CARDIOL A, V277, P772
[6]   A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE [J].
FISCHMAN, DL ;
LEON, MB ;
BAIM, DS ;
SCHATZ, RA ;
SAVAGE, MP ;
PENN, I ;
DETRE, K ;
VELTRI, L ;
RICCI, D ;
NOBUYOSHI, M ;
CLEMAN, M ;
HEUSER, R ;
ALMOND, D ;
TEIRSTEIN, PS ;
FISH, RD ;
COLOMBO, A ;
BRINKER, J ;
MOSES, J ;
SHAKNOVICH, A ;
HIRSHFELD, J ;
BAILEY, S ;
ELLIS, S ;
RAKE, R ;
GOLDBERG, S .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) :496-501
[7]   Three-year follow-up after implantation of metallic coronary-artery stents [J].
Kimura, T ;
Yokoi, H ;
Nakagawa, Y ;
Tamura, T ;
Kaburagi, S ;
Sawada, Y ;
Sato, Y ;
Yokoi, H ;
Hamasaki, N ;
Nosaka, H ;
Nobuyoshi, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (09) :561-566
[8]   STENTING FOR ELASTIC RECOIL DURING CORONARY ANGIOPLASTY OF THE LEFT MAIN CORONARY-ARTERY [J].
MACAYA, C ;
ALFONSO, F ;
INIGUEZ, A ;
GOICOLEA, J ;
HERNANDEZ, R ;
ZARCO, P .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (01) :105-107
[9]   LEFT MAIN CORONARY ANGIOPLASTY - EARLY AND LATE RESULTS OF 127 ACUTE AND ELECTIVE PROCEDURES [J].
OKEEFE, JH ;
HARTZLER, GO ;
RUTHERFORD, BD ;
MCCONAHAY, DR ;
JOHNSON, WL ;
GIORGI, LV ;
LIGON, RW .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 64 (03) :144-147