Air sampling with porous solid-phase microextraction fibers

被引:197
作者
Koziel, J [1 ]
Jia, MY [1 ]
Pawliszyn, J [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
关键词
D O I
10.1021/ac000518l
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new, rapid air sampling/sample preparation methodology was investigated using adsorptive solid-phase microextraction (SPME) fiber coatings and nonequilibrium conditions for volatile organic compounds (VOCs), This method is the fastest extraction technique for air sampling at typical airborne VOC concentrations. A theoretical model for the extraction was formulated based on the diffusion through the interface between the sampled (bulk) air and the SPME coating Parameters that affect the extraction process including sampling time, air velocity, air temperature, and relative humidity were investigated with the porous (solid) PDMS/DVB and Carboxen/PDMS coatings. Very short sampling times from 5 s to 1 min were used to minimize the effects of competitive adsorption and to calibrate the extraction process in the initial linear extraction region. The predicted amounts of extracted mass compared well with the measured amounts of target VOCs. Findings presented in this study extend the existing fundamental knowledge related to sampling/sample preparation with SPME, thereby enabling the development of new sampling devices for the rapid sampling of air, headspace, water, and soil.
引用
收藏
页码:5178 / 5186
页数:9
相关论文
共 31 条
[1]   Solid phase microextraction in headspace analysis. Dynamics in non-steady state mass transfer [J].
Ai, J .
ANALYTICAL CHEMISTRY, 1998, 70 (22) :4822-4826
[2]   Solid phase microextraction for quantitative analysis in nonequilibrium situations [J].
Ai, J .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1230-1236
[3]   Headspace solid phase microextraction. Dynamics and quantitative analysis before reaching a partition equilibrium [J].
Ai, J .
ANALYTICAL CHEMISTRY, 1997, 69 (16) :3260-3266
[4]  
[Anonymous], 1994, AIR POLLUT CONTROL
[5]  
AUGUSTO F, UNPUB ANAL CHEM
[6]   ANALYSIS OF ENVIRONMENTAL AIR SAMPLES BY SOLID-PHASE MICROEXTRACTION AND GAS-CHROMATOGRAPHY ION-TRAP MASS-SPECTROMETRY [J].
CHAI, M ;
PAWLISZYN, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1995, 29 (03) :693-701
[7]   Design of an automated analysis system for the determination of organic compounds in continuous air stream using solid-phase microextraction [J].
Eisert, R ;
Pawliszyn, J ;
Barinshteyn, G ;
Chambers, D .
ANALYTICAL COMMUNICATIONS, 1998, 35 (06) :187-189
[8]  
FULLER EN, 1996, INDIAN CHEM ENG, V58, P19
[9]   Theory of analyte extraction by selected porous polymer SPME fibres [J].
Górecki, T ;
Yu, XM ;
Pawliszyn, J .
ANALYST, 1999, 124 (05) :643-649
[10]  
Gorecki T., 1999, APPL SOLID PHASE MIC