Treatment of landfill leachate by combined aged-refuse bioreactor and electro-oxidation

被引:118
作者
Lei, Yangming
Shen, Zhemin [1 ]
Huang, Renhua
Wang, Wenhua
机构
[1] Shanghai Jiao Tong Univ, Sch Environm Sci & Engn, Shanghai 200240, Peoples R China
[2] Shanghai Waste Laogang Disposal Plant, Shanghai 201302, Peoples R China
基金
中国国家自然科学基金;
关键词
electro-oxidation; aged-refuse bioreactor; landfill leachate; gas diffusion electrode; chlorinated organic compound;
D O I
10.1016/j.watres.2007.02.044
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Two-stage aged-refuse bioreactor (ARB) was applied to treat landfill leachate in Shanghai Waste Laogang Disposal Plant. The removal efficiencies of chemical oxygen demand (COD), biological oxygen demand (BOD), total organic carbon (TOC), total nitrogen (TN) and ammonia nitrogen (NH3-N) of landfill leachate treated by the two-stage bioreactor system were 98.5%, 99.9%, 98.0%, 64.2% and 99.9%, respectively. The COD and BOD in the second stage effluent were 239 and 7 mgl(-1), respectively. Thus three types of electrolysis were employed to further treat the second effluent, undivided electrolysis (UDE), divided electrolysis (DE) with Ti/PbO2 cathode and DE with gas diffusion cathode. All electrolysis processes possessed good color removal effect, while the DE with gas diffusion cathode had the best TOC removal effect. The optimum electrolysis time of leachate was 30 min. The TOC removal efficiencies were 51.4% and 39.7% in anolyte and catholyte, respectively, after 30 min electrolysis at 5V In addition, the DE with gas diffusion cathode showed the least energy consumption of 9.8 kWh m(-3) at 30 min. The organic pollutants in the leachate were analyzed through a gas chromatography coupled with mass spectrometry (GC-MS) system. Through the two-stage ARB, the species and concentrations of organic pollutants in landfill leachate reduced greatly Several chlorinated organic compounds were detected in the effluent after the UDE and the anolyte of the DE. In addition, the concentration of absorbable organic halogens (AOX) increased greatly during the electrolysis. Hence, careful consideration should be given in the application of electro -oxidation into the treatment of chloride-containing wastewater. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2417 / 2426
页数:10
相关论文
共 33 条
[1]  
[Anonymous], 1995, Standard methods for examination of water and waste water, V19th
[2]   ELECTROCHEMICAL DESTRUCTION OF ANILINE AND 4-CHLOROANILINE FOR WASTE-WATER TREATMENT USING A CARBON-PTFE O-2-FED CATHODE [J].
BRILLAS, E ;
BASTIDA, RM ;
LLOSA, E ;
CASADO, J .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1995, 142 (06) :1733-1741
[3]   Mineralization of 2,4-D by advanced electrochemical oxidation processes [J].
Brillas, E ;
Calpe, JC ;
Casado, J .
WATER RESEARCH, 2000, 34 (08) :2253-2262
[4]   Aniline degradation by Electro-Fenton® and peroxi-coagulation processes using a flow reactor for wastewater treatment [J].
Brillas, E ;
Casado, J .
CHEMOSPHERE, 2002, 47 (03) :241-248
[5]   Electrochemical extraction of oxygen from air via hydroperoxide ion [J].
Brillas, E ;
Maestro, A ;
Moratalla, M ;
Casado, J .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 1997, 27 (01) :83-92
[6]   Electrochemical technologies in wastewater treatment [J].
Chen, GH .
SEPARATION AND PURIFICATION TECHNOLOGY, 2004, 38 (01) :11-41
[7]  
Chen XJ, 2005, WATER SA, V31, P127
[8]   INDIRECT OXIDATION EFFECT IN ELECTROCHEMICAL OXIDATION TREATMENT OF LANDFILL LEACHATE [J].
CHIANG, LC ;
CHANG, JE ;
WEN, TC .
WATER RESEARCH, 1995, 29 (02) :671-678
[9]  
Christensen T.H., 1989, Sanitary landfilling: Process, technology and environmental impact, P29
[10]  
COMNINELLIS C, 1995, J APPL ELECTROCHEM, V25, P23