Agreement and reproducibility of automatic versus manual measurement of QT interval and QT dispersion

被引:118
作者
Savelieva, I [1 ]
Yi, G [1 ]
Guo, XH [1 ]
Hnatkova, K [1 ]
Malik, M [1 ]
机构
[1] St Georges Hosp, Sch Med, Dept Cardiol Sci, London SW17 0RE, England
关键词
D O I
10.1016/S0002-9149(97)00927-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To determine whether the automatic measurement of the QT interval is consistent with the manual measurement, this study evaluated the reproducibility and agreement of both methods in 70 normal subjects and 54 patients with hypertrophic cardiomyopathy. The mean, minimum, and maximum QT interval and QT dispersion were computed in a set of 6 consecutive electrocardiograms (3 in the supine and 3 in the standing position) obtained from each subject. The automatic method determined the T-wave end as the intersect of the least-squares-fit line around the tangent to the T-wave downslope with the isoelectric baseline. Manual measurements were obtained using a high-resolution digitizing board. QT dispersion was defined as the difference between the maximum and minimum QT interval and as standard deviations of the QT interval duration in all and precordial leads. In patients with hypertrophic cardiomyopathy, the absolute values of the QT interval and QT dispersion were significantly higher than those in normal subjects (p <0.0001). In both groups, the intrasubject variability of the QT interval was significantly lower with automatic than with manual measurement (p <0.05). The agreement between automatic and manual QT interval measurements was surprisingly poor, but it was better in patients with, hypertrophic cardiomyopathy (r(2) = 0.46 to 0.67) than in normal subjects (r(2) = 0.10 to 0.25), In both groups, the reproducibility and agreement of both methods for QT dispersion were significantly poorer than for QT interval. Hence, the automatic QT interval measurements are more stable and reproducible than manual measurement, but the lack of agreement between manual and automatic measurement suggests that clinical experience gained with manual assessment cannot be applied blindly to data obtained from the automatic systems. (C) 1998 by Excerpta Medica, Inc.
引用
收藏
页码:471 / 477
页数:7
相关论文
共 27 条
[1]   ERRORS IN THE VISUAL DETERMINATION OF CORRECTED QT (QTC) INTERVAL DURING ACUTE MYOCARDIAL-INFARCTION [J].
AHNVE, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 5 (03) :699-702
[2]   QTC PROLONGATION MEASURED BY STANDARD 12-LEAD ELECTROCARDIOGRAPHY IS AN INDEPENDENT RISK FACTOR FOR SUDDEN-DEATH DUE TO CARDIAC-ARREST [J].
ALGRA, A ;
TIJSSEN, JGP ;
ROELANDT, JRTC ;
POOL, J ;
LUBSEN, J .
CIRCULATION, 1991, 83 (06) :1888-1894
[3]   AUTOMATED MEASUREMENT OF QT INTERVAL DISPERSION FROM HARD-COPY ECGS [J].
BHULLAR, HK ;
FOTHERGILL, JC ;
GODDARD, WP ;
DEBONO, DP .
JOURNAL OF ELECTROCARDIOLOGY, 1993, 26 (04) :321-331
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   COMPARISON OF QT DISPERSION IN HYPERTROPHIC CARDIOMYOPATHY BETWEEN PATIENTS WITH AND WITHOUT VENTRICULAR ARRHYTHMIAS AND SUDDEN-DEATH [J].
BUJA, G ;
MIORELLI, M ;
TURRINI, P ;
MELACINI, P ;
NAVA, A .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (12) :973-976
[6]  
BUTROUS GS, 1989, CLIN ASPECTS VENTRIC, P41
[7]   IMPORTANCE OF LEAD SELECTION IN QT INTERVAL MEASUREMENT [J].
COWAN, JC ;
YUSOFF, K ;
MOORE, M ;
AMOS, PA ;
GOLD, AE ;
BOURKE, JP ;
TANSUPHASWADIKUL, S ;
CAMPBELL, RWF .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 61 (01) :83-87
[8]  
DAVEY P, 1994, BRIT HEART J, V71, P268
[9]  
DAY CP, 1990, BRIT HEART J, V63, P342
[10]  
Fu GS, 1997, EUR HEART J, V18, P281