Symptomatic improvement in dyspnea following tracheobronchial metallic stenting for malignant airway obstruction

被引:17
作者
Tanigawa, N
Sawada, S
Okuda, Y
Kobayashi, M
Mishima, K
机构
[1] Kansai Med Univ, Dept Radiol, Moriguchi, Osaka 5708507, Japan
[2] Tottori Municipal Hosp, Osaka, Japan
[3] Mihagino Hosp, Osaka, Japan
关键词
lung neoplasms; stents and prostheses; trachea; bronchi; stenosis or obstruction;
D O I
10.1080/028418500127345857
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Purpose: To investigate the value and limitation of Gianturco expandable metallic stenting for patients with dyspnea due to stenotic tracheobronchial lesions associated with malignancies. Material and Method's: We treated 55 lesions of 44 patients with obstructing stenotic tracheobronchial lesions related to end-stage malignancies by Gianturco expandable metallic stents (EMSs). Results: In 42 of 44 patients, the dyspnea subjectively improved after the procedure (95.5%). An improvement over one grade of the Hugh-Jones classification was shown in 79.5% (35/44); in 80% (20 of 25 patients) with intraluminal tumor and in 78.9% (15 of 19 patients) with extrinsic compression. Seven of the 44 patients developed dyspnea related to re-stenosis of 10 lesions and 1 of these patients developed dyspnea related to re-re-stenosis during follow-up. The mean duration of survival was 4.3 months in patients who underwent stenting. No significant differences in survival rates and primary patency rates were seen in patients with extrinsic compression compared to patients with intraluminal tumors. Conclusion: Gianturco EMS therapy was valuable in patients who suffered from dyspnea due to airway stenosis causing obstruction.
引用
收藏
页码:425 / 428
页数:4
相关论文
共 9 条
[1]
BOLLIGER CT, 1993, CHEST, V104, P1653, DOI 10.1378/chest.104.6.1653
[2]
EXPANDABLE METAL STENTS FOR TRACHEOBRONCHIAL OBSTRUCTION [J].
EGAN, AM ;
DENNIS, C ;
FLOWER, CDR .
CLINICAL RADIOLOGY, 1994, 49 (03) :162-165
[3]
GEORGE PJ, 1990, LANCET, V335, P581
[4]
HUGHJONES P, 1952, BRIT MED J, V12, P65
[5]
TREATMENT OF MALIGNANT TRACHEOBRONCHIAL STENOSIS BY DACRON MESH-COVERED Z-STENTS [J].
KISHI, K ;
KOBAYASHI, H ;
SURUDA, T ;
OHATA, M ;
SONOMURA, T ;
NISHIDA, N ;
SATO, M ;
YAMADA, R .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1994, 17 (01) :33-35
[6]
Partially covered Gianturco stent for tracheobronchial stricture caused by intraluminal tumor [J].
Miyayama, S ;
Matsui, O ;
Kamimura, R ;
Kakuta, K ;
Takashima, T .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 20 (01) :60-62
[7]
INDICATIONS FOR AN EXPANDABLE METALLIC STENT FOR TRACHEOBRONCHIAL STENOSIS [J].
NOMORI, H ;
KOBAYASHI, R ;
KODERA, K ;
MORINAGA, S ;
OGAWA, K .
ANNALS OF THORACIC SURGERY, 1993, 56 (06) :1324-1328
[8]
Gianturco-Rosch Z stents in tracheobronchial stenoses [J].
Petersen, BD ;
Uchida, BT ;
Barton, RE ;
Keller, FS ;
Rosch, J .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1995, 6 (06) :925-931
[9]
MALIGNANT TRACHEOBRONCHIAL OBSTRUCTIVE LESIONS - TREATMENT WITH GIANTURCO EXPANDABLE METALLIC STENTS [J].
SAWADA, S ;
TANIGAWA, N ;
KOBAYASHI, M ;
FURUI, S ;
OHTA, Y .
RADIOLOGY, 1993, 188 (01) :205-208