Solvent exchange using hollow fiber prior to separation and determination of some antioxidants by high performance liquid chromatography

被引:5
作者
Farajzadeh, Mir Ali
Jonsson, Jan Ake
机构
[1] Lund Univ, Dept Analyt Chem, S-22100 Lund, Sweden
[2] Urmia Univ, Fac Sci, Dept Chem, Orumiyeh, Iran
关键词
hollow fiber; solvent exchange; antioxidants; high performance liquid chromatography; ONLINE MEMBRANE EXTRACTION; VOLATILE ORGANIC-COMPOUNDS; ENHANCED PEAK RESPONSES; SAMPLE PREPARATION; PRECONCENTRATION; SYSTEM;
D O I
10.1016/j.aca.2007.05.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study presents a simple and rapid solvent exchange procedure using a hollow fiber. Antioxidants (Irganox 1010, Irganox 1076 and Irgafos 168) and solvents such as tetrahydrofuran (THF), carbon tetrachloride and toluene were selected as model compounds and sample solvents, respectively. After injection of the sample solution into the hollow fiber and solvent evaporation, the precipitated analytes in lumen and pores of the fiber were washed with methanol (the mobile phase for separation and determination by HPLC-diode array detection) and good chromatographic peaks were obtained. The effect of different parameters such as fiber length, volumes of sample and washing solvents were investigated and the optimum conditions were selected. The repeatability of the method was tested and it was found that the relative standard deviation (R.S.D.) was less than 10% for all analytes. Also enrichment factors of 3.03, 2.21 and 1.19 times were obtained for Irganox 1010, Irganox 1076 and Irgafos 168, respectively, when 200 mu L sample and 50 mu L methanol (washing solvent) were used. (c) 2007 Elsevier BX All rights reserved.
引用
收藏
页码:75 / 80
页数:6
相关论文
共 22 条
[1]   ON THE OBSERVATION OF ENHANCED PEAK RESPONSES DUE TO SOLVENT INTERACTIONS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - COMMENT [J].
BERRIDGE, JC .
JOURNAL OF CHROMATOGRAPHY, 1986, 369 (01) :265-268
[2]   Hollow fiber membrane concentrator for on-line preconcentration [J].
Bishop, EJ ;
Mitra, S .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1046 (1-2) :11-17
[3]   HPLC method with on-line SPE preconcentration for quantification of permethric acid sorption to goethite [J].
Bjarnholt, N ;
Svensmark, B ;
Hansen, HCB .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2004, 84 (04) :303-314
[4]  
Dolan JW, 2004, LC GC N AM, V22, P26
[5]   Rapid antibiotic drug monitoring:: Meropenem and ceftazidime determination in serum and bronchial secretions by high-performance liquid chromatography-integrated sample preparation [J].
Ehrlich, M ;
Daschner, FD ;
Kümmerer, K .
JOURNAL OF CHROMATOGRAPHY B, 2001, 751 (02) :357-363
[6]   On-line membrane extraction liquid chromatography for monitoring semi-volatile organics in aqueous matrices [J].
Guo, XM ;
Mitra, S .
JOURNAL OF CHROMATOGRAPHY A, 2000, 904 (02) :189-196
[7]   CHANNELLING IN PACKED COLUMNS [J].
HILL, S .
CHEMICAL ENGINEERING SCIENCE, 1952, 1 (06) :247-253
[8]   Inline gas chromatographic tracer analysis: An alternative to conventional sampling and laboratory analysis for partitioning tracer tests [J].
Jawitz, JW ;
Annable, MD ;
Clark, CJ ;
Puranik, S .
INSTRUMENTATION SCIENCE & TECHNOLOGY, 2002, 30 (04) :415-426
[9]  
Jonsson JÅ, 2001, ADV CHROMATOGR, V41, P53
[10]  
Jönsson JÅ, 2001, J SEP SCI, V24, P495, DOI 10.1002/1615-9314(20010801)24:7<495::AID-JSSC495>3.0.CO