Biocompatibility and biofouling of MEMS drug delivery devices

被引:424
作者
Voskerician, G
Shive, MS
Shawgo, RS
von Recum, H
Anderson, JM
Cima, MJ
Langer, R
机构
[1] Case Western Reserve Univ, Inst Pathol, Dept Biomed Engn, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Dept Macromol Sci, Cleveland, OH 44106 USA
[3] MIT, Dept Chem Engn, Cambridge, MA 02139 USA
[4] MIT, Dept Mat Sci & Engn, Cambridge, MA 02139 USA
关键词
biocompatibility; biofouling; MEMS component materials; exudate analysis; material surface analysis;
D O I
10.1016/S0142-9612(02)00565-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The biocompatibility and biofouling of the microfabrication materials for a MEMS drug delivery device have been evaluated. The in vivo inflammatory and wound healing response of MEMS drug delivery component materials, metallic gold, silicon nitride, silicon dioxide, silicon, and SU-8(TM) photoresist, were evaluated using the cage implant system. Materials, placed into stainless-steel cages, were implanted subcutaneously in a rodent model. Exudates within the cage were sampled at 4, 7, 14, and 21 days, representative of the stages of the inflammatory response, and leukocyte concentrations (leukocytes/mul) were measured. Overall, the inflammatory responses elicited by these materials were not significantly different than those for the empty cage controls over the duration of the study. The material surface cell density (macrophages or foreign body giant cells, FBGCs), an indicator of in vivo biofouling, was determined by scanning electron microscopy of materials explanted at 4, 7, 14, and 21 days. The adherent cellular density of gold, silicon nitride, silicon dioxide, and SU-8(TM) were comparable and statistically less (p<0.05) than silicon. These analyses identified the MEMS component materials, gold, silicon nitride, silicon dioxide, SU-8(TM), and silicon as biocompatible, with gold, silicon nitride, silicon dioxide, and SU-8(TM) showing reduced biofouling. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1959 / 1967
页数:9
相关论文
共 23 条
[1]   Issues and perspectives on the biocompatibility and immunotoxicity evaluation of implanted controlled release systems [J].
Anderson, JM ;
Langone, JJ .
JOURNAL OF CONTROLLED RELEASE, 1999, 57 (02) :107-113
[2]  
ANDERSON JM, 1996, INFLAMMATIION WOUND, pCH4
[3]   Hemocompatibility, biocompatibility, inflammatory and in vivo studies of primary reference materials low-density polyethylene and polydimethylsiloxane:: A review [J].
Bélanger, MC ;
Marois, Y .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2001, 58 (05) :467-477
[4]   PROTEIN ADSORPTION AND ENDOTHELIAL-CELL ATTACHMENT AND PROLIFERATION ON PAPI-BASED ADDITIVE MODIFIED POLY(ETHER URETHANE UREAS) [J].
BRUNSTEDT, MR ;
ZIATS, NP ;
SCHUBERT, M ;
STACK, S ;
ROSECAPRARA, V ;
HILTNER, PA ;
ANDERSON, JM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (04) :499-510
[5]  
Certa U, 1999, CHIMIA, V53, P57
[6]   Micro-systems in biomedical applications [J].
Dario, P ;
Carrozza, MC ;
Benvenuto, A ;
Menciassi, A .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2000, 10 (02) :235-244
[7]  
Desai TA, 1998, BIOTECHNOL BIOENG, V57, P118, DOI 10.1002/(SICI)1097-0290(19980105)57:1<118::AID-BIT14>3.0.CO
[8]  
2-G
[9]   FACTORS INFLUENCING THE BIOCOMPATIBILITY OF INSERTABLE SILICON MICROSHAFTS IN CEREBRAL-CORTEX [J].
EDELL, DJ ;
TOI, VV ;
MCNEIL, VM ;
CLARK, LD .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (06) :635-643