Evaluation of porcine myocardial microvascular permeability and fractional vascular volume using 64-slice helical computed tomography (CT)

被引:37
作者
Daghini, Elena
Primak, Andrew N.
Chade, Alejandro R.
Zhu, Xiangyang
Ritman, Erik L.
McCollough, Cynthia H.
Lerman, Lilach O.
机构
[1] Mayo Clin & Mayo Fdn, Coll Med, Div Nephrol & Hypertens, Dept Med, Rochester, MN 55905 USA
[2] Mayo Clin & Mayo Fdn, Coll Med, Div Cardiovasc Dis, Dept Radiol, Rochester, MN 55905 USA
[3] Mayo Clin & Mayo Fdn, Coll Med, Dept Physiol & Biomed Engn, Rochester, MN 55905 USA
关键词
electron beam CT; 64-slice multidetector CT; microvascular permeability; Patlak analysis; indicator-dilution theory; myocardial blood volume;
D O I
10.1097/01.rli.0000258086.78179.90
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Objectives: Myocardial microvascular permeability-surface area product (MPSP) and fractional vascular volume (FVV), indices of endothelial function and microvascular perfusion, can be noninvasively evaluated by electron beam computed tomography (EBCT), but it remains unknown whether comparable assessments can be obtained with 64-slice multidetector CT (CT-64). Methods: We studied 12 pigs with both EBCT and CT-64 in randomized order 1 week apart, before and during IV adenosine infusion. Myocardial attenuation changes in the cardiac wall were assessed after a central-venous injection of iopamidol. Time-attenuation curves were analyzed using both indicator-dilution and Patlak models to calculate MPSP and FVV. Results: CT-64 and EBCT assessments of basal MPSP obtained by the Patlak method were similar (0.37 +/- 0.03 vs. 0.37 +/- 0.04 mL/min/g), as was its response to adenosine, and correlated significantly (r = 0.87). Patlak FVV was also similar between CT-64 and EBCT at baseline (0.08 +/- 0.02 vs. 0.07 +/- 0.02 mL blood/mL) and during adenosine, and correlated well (r = 0.93). MPSP and FVV estimated by the indicator-dilution method were not significantly correlated. Conclusions: CT-64 assessments of myocardial MPSP and FVV may not be reliable when using indicator-dilution analysis, likely due to its sensitivity to scan duration. However, CT-64 assessments obtained using the Patlak model are feasible.
引用
收藏
页码:274 / 282
页数:9
相关论文
共 30 条
[1]
Long-term follow-up of patients with mild coronary artery disease and endothelial dysfunction [J].
Al Suwaidi, J ;
Hamasaki, S ;
Higano, ST ;
Nishimura, RA ;
Holmes, DR ;
Lerman, A .
CIRCULATION, 2000, 101 (09) :948-954
[2]
Prediction of coronary events with electron beam computed tomography [J].
Arad, Y ;
Spadaro, LA ;
Goodman, K ;
Newstein, D ;
Guerci, AD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (04) :1253-1260
[3]
Validation of minimally invasive measurement of myocardial perfusion using electron beam computed tomography and application in human volunteers [J].
Bell, MR ;
Lerman, LO ;
Rumberger, JA .
HEART, 1999, 81 (06) :628-635
[4]
Endothelin type A receptor antagonism restores myocardial perfusion response to adenosine in experimental hypercholesterolemia [J].
Bonetti, PO ;
Best, PJM ;
Rodriguez-Porcel, M ;
Holmes, DR ;
Lerman, LO ;
Lerman, A .
ATHEROSCLEROSIS, 2003, 168 (02) :367-373
[5]
Simvastatin preserves myocardial perfusion and coronary microvascular permeability in experimental hypercholesterolemia independent of lipid lowering [J].
Bonetti, PO ;
Wilson, SH ;
Rodriguez-Porcel, M ;
Holmes, DR ;
Lerman, LO ;
Lerman, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (03) :546-554
[6]
ACCF/AHA clinical competence statement on cardiac imaging with computed tomography and magnetic resonance - A report of the American College of Cardiology Foundation/American Heart Association/American college of Physicians Task Force on clinical competence and training [J].
Budoff, MJ ;
Cohen, MC ;
Garcia, MJ ;
Hodgson, JM ;
Hundley, WG ;
Lima, JAC ;
Manning, WJ ;
Pohost, GM ;
Raggi, PM ;
Rodgers, GP ;
Rumberger, JA ;
Taylor, AJ ;
Creager, MA ;
Hirshfeld, JW ;
Lorell, BH ;
Merli, G ;
Rodgers, GP ;
Tracy, CM ;
Weitz, HH .
CIRCULATION, 2005, 112 (04) :598-617
[7]
1ST-PASS ENTRY OF NONIONIC CONTRAST AGENT INTO THE MYOCARDIAL EXTRAVASCULAR SPACE - EFFECTS ON RADIOGRAPHIC ESTIMATES OF TRANSIT-TIME AND BLOOD-VOLUME [J].
CANTY, JM ;
JUDD, RM ;
BRODY, AS ;
KLOCKE, FJ .
CIRCULATION, 1991, 84 (05) :2071-2078
[8]
First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[9]
Glomerular filtration rate measured using the Patlak plot technique and contrast-enhanced dynamic MRI with different amounts of gadolinium-DTPA [J].
Hackstein, N ;
Kooijman, H ;
Tomaselli, S ;
Rau, WS .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (03) :406-414
[10]
Measurement of single-kidney glomerular filtration rate using a contrast-enhanced dynamic gradient-echo sequence and the Rutland-Patlak plot technique [J].
Hackstein, N ;
Heckrodt, J ;
Rau, WS .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (06) :714-725