Evaluation of four methods for rapid identification of Staphylococcus aureus from blood cultures

被引:37
作者
Speers, DJ [1 ]
Olma, TR
Gilbert, GL
机构
[1] Westmead Hosp, Ctr Infect Dis, Inst Clin Pathol & Med Res, Westmead, NSW 2145, Australia
[2] Westmead Hosp, Microbiol Lab Serv, Inst Clin Pathol & Med Res, Westmead, NSW 2145, Australia
关键词
D O I
10.1128/JCM.36.4.1032-1034.1998
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The identification of Staphylococcus aureus directly from blood cultures is clinically relevant, but it requires a test that is both rapid and reliable. Previously, biochemical, immunological, tube coagulase, and thermostable-endonuclease methods have shown variable sensitivity and specificity, Testing directly from blood culture broth has not been described for the lates kit Staphaurex Plus (Murex Diagnostics Ltd.), and the modified conventional tests have not been used with the never, continuously monitored blood culture systems, In addition, the commercial RAPIDEC staph kit (bioMerieux Vitek, Inc.) has been used to detect S. aureus directly from the Vital blood culture system (bioMerieux, Marcy l'Etoile, France), but its performance has not been evaluated with other continuously monitored systems, A total of 201 clinical blood cultures (BACTEC 9240 culture system; Johnston Laboratories, Inc.) in which a Gram stain showed gram-positive cocci resembling staphylococci were evaluated prospectively. The Staphaurex Plus kit, the tube coagulase test, the thermostable-endonuclease test, and the RAPIDEC staph kit were compared. The sensitivities were 23, 92, 85, and 98% and the specificities were 99, 100, 93, and 100%, respectively, The RAPIDEC staph kit was the most reliable test, with a diagnostic accuracy comparable to that of the best published results for any of the rapid tests, However, it was the most expensive of the tests and relatively labor-intensive, The tube coagulase test was also sensitive, the simplest to perform, and inexpensive.
引用
收藏
页码:1032 / 1034
页数:3
相关论文
共 13 条
[1]  
BERGH K, 1986, ACTA PATH MICRO IM B, V94, P291
[2]   DIRECT IDENTIFICATION OF STAPHYLOCOCCUS-AUREUS IN BLOOD CULTURES BY DETECTION OF THE GENE ENCODING THE THERMOSTABLE NUCLEASE OR THE GENE-PRODUCT [J].
BRAKSTAD, OG ;
MAELAND, JA .
APMIS, 1995, 103 (03) :209-218
[3]   RAPID, DIRECT IDENTIFICATION OF STAPHYLOCOCCUS-AUREUS AND STREPTOCOCCUS-PNEUMONIAE FROM BLOOD CULTURES USING COMMERCIAL IMMUNOLOGICAL KITS AND MODIFIED CONVENTIONAL TESTS [J].
DAVIS, TE ;
FULLER, DD ;
AESCHLEMAN, EC .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 1992, 15 (04) :295-300
[4]   MEDIUM DEPENDENCE FOR RAPID DETECTION OF THERMONUCLEASE ACTIVITY IN BLOOD CULTURE BROTHS [J].
FARUKI, H ;
MURRAY, P .
JOURNAL OF CLINICAL MICROBIOLOGY, 1986, 24 (03) :482-483
[5]  
GEARY C, 1991, MED LAB SCI, V48, P99
[6]   EVALUATION OF RAPID IDENTIFICATION OF GRAM-POSITIVE COCCI IN POSITIVE BLOOD CULTURES BY USE OF THE AUTOMICROBIC SYSTEM GRAM-POSITIVE IDENTIFICATION CARD [J].
HAMOUDI, AC ;
MARCON, MJ ;
CANNON, HJ .
JOURNAL OF CLINICAL MICROBIOLOGY, 1984, 20 (02) :171-174
[7]   RAPID IDENTIFICATION OF STAPHYLOCOCCUS-AUREUS FROM BLOOD CULTURE BOTTLES BY A CLASSIC 2-HOUR TUBE COAGULASE TEST [J].
MCDONALD, CL ;
CHAPIN, K .
JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (01) :50-52
[8]  
MITCHELL CJ, 1991, MED LAB SCI, V48, P106
[9]   Evaluation of a commercial test kit for rapid detection of Staphylococcus aureus in blood cultures [J].
Neyret, C ;
Lelievre, H ;
Lina, G ;
Vandenesch, F ;
Etienne, J .
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1997, 16 (02) :165-166
[10]   EVALUATION OF SEVERAL COMMERCIAL BIOCHEMICAL AND IMMUNOLOGICAL METHODS FOR RAPID IDENTIFICATION OF GRAM-POSITIVE COCCI DIRECTLY FROM BLOOD CULTURES [J].
RAPPAPORT, T ;
SAWYER, KP ;
NACHAMKIN, I .
JOURNAL OF CLINICAL MICROBIOLOGY, 1988, 26 (07) :1335-1338