On-line sample treatment - Capillary gas chromatography

被引:29
作者
Goosens, EC [1 ]
de Jong, D
de Jong, GJ
Brinkman, UAT
机构
[1] Solvay Duphar BV, NL-1380 DA Weesp, Netherlands
[2] Gist Brocades, Delft, Netherlands
[3] Univ Groningen, Ctr Pharm, Groningen, Netherlands
[4] Free Univ Amsterdam, Dept Analyt Chem, NL-1081 HV Amsterdam, Netherlands
关键词
gas chromatography; sample pretreatment; coupling on-line to capillary GC; robotization;
D O I
10.1007/BF02466538
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Sample pretreatment is often the bottleneck of a trace level analytical procedure. In order to increase performance, increasing attention is therefore being devoted to combining sample pretreatment on-line with the separation technique that has to be used. In the present review, a variety of procedures in use today for sample treatment coupled on-line to capillary gas chromatography (GC) is briefly discussed. Special attention is devoted to coupled-column techniques such as SPE-GC and LC-GC (SPE, solid-phase extraction; LC, column liquid chromatography) which are topics of much current interest, also because of their frequent use in so-called hyphenated systems.
引用
收藏
页码:313 / 345
页数:33
相关论文
共 214 条
[1]  
[Anonymous], 1984, HEAD SPACE ANAL RELA
[2]  
[Anonymous], 1993, SUPERCRITICAL FLUID
[3]  
ARTHUR CL, 1992, HRC-J HIGH RES CHROM, V15, P741
[4]   DETERMINATION OF LOW PARTS PER BILLION LEVELS OF AMINES IN URINE BY LIQUID MEMBRANE SAMPLE CLEANUP DIRECTLY COUPLED TO A GAS-LIQUID CHROMATOGRAPH [J].
AUDUNSSON, G .
ANALYTICAL CHEMISTRY, 1988, 60 (13) :1340-1347
[5]  
AUDUNSSON GA, 1986, ANAL CHEM, V58, P2183
[6]   DESIGN AND EVALUATION OF A NEW PHASE SEPARATOR FOR LIQUID-LIQUID-EXTRACTION IN FLOW SYSTEMS [J].
BACKSTROM, K ;
DANIELSSON, LG ;
NORD, L .
ANALYTICA CHIMICA ACTA, 1985, 169 (MAR) :43-49
[7]   ONLINE COUPLING OF A GAS-CHROMATOGRAPH TO A CONTINUOUS LIQUID LIQUID EXTRACTOR [J].
BALLESTEROS, E ;
GALLEGO, M ;
VALCARCEL, M .
ANALYTICAL CHEMISTRY, 1990, 62 (15) :1587-1591
[8]   AUTOMATIC-DETERMINATION OF N-METHYLCARBAMATE PESTICIDES BY USING A LIQUID LIQUID EXTRACTOR DERIVATIZATION MODULE COUPLED ONLINE TO A GAS-CHROMATOGRAPH EQUIPPED WITH A FLAME IONIZATION DETECTOR [J].
BALLESTEROS, E ;
GALLEGO, M ;
VALCARCEL, M .
JOURNAL OF CHROMATOGRAPHY, 1993, 633 (1-2) :169-176
[9]   AUTOMATIC GAS-CHROMATOGRAPHIC DETERMINATION OF N-METHYLCARBAMATES IN MILK WITH ELECTRON-CAPTURE DETECTION [J].
BALLESTEROS, E ;
GALLEGO, M ;
VALCARCEL, M .
ANALYTICAL CHEMISTRY, 1993, 65 (13) :1773-1778
[10]   GAS-CHROMATOGRAPHIC DETERMINATION OF PHENOL COMPOUNDS WITH AUTOMATIC CONTINUOUS EXTRACTION AND DERIVATIZATION [J].
BALLESTEROS, E ;
GALLEGO, M ;
VALCARCEL, M .
JOURNAL OF CHROMATOGRAPHY, 1990, 518 (01) :59-67