Sensorless rotor position estimation of an interior permanent-magnet motor from initial states

被引:177
作者
Ha, JI [1 ]
Ide, K
Sawa, T
Sul, SK
机构
[1] Samsung Elect Co, Mechatron Ctr, Gyeonggi 442742, South Korea
[2] Yaskawa Elect Co, Mechatron R&D Dept, Kitakyushu, Fukuoka 8038530, Japan
[3] Seoul Natl Univ, Sch Elect Engn & Comp Sci, Seoul 151742, South Korea
关键词
motor drives; position estimation; sensorless control;
D O I
10.1109/TIA.2003.811781
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper describes a torque, speed, or position control method at standstill and low speed in the interior permanent-magnet motor (IPMM) drive. system without any rotational transducer. While IPMMs have originally magnetic saliency, it varies according to the load conditions and the control performance can be easily degraded. In this paper, the saliency or impedance difference is used as the conventional methods and, nevertheless, in order to amplify the difference containing the information of the rotor angle and to maintain a reasonable performance under any load condition a high-frequency injection scheme is proposed. A speed and position estimation scheme based on the characteristics of the high-frequency impedance is proposed. The scheme extracts the high-frequency impedance components related to the rotor position. An initial angle estimation scheme for starting from an arbitrary rotor position is also proposed. It can distinguish the north magnetic pole position from the south one in several decade milliseconds. The proposed scheme enables position control of a transducerless or position-sensorless IPMM. The experimental results clarify the satisfactory operation of the proposed position control algorithm under any load condition.
引用
收藏
页码:761 / 767
页数:7
相关论文
共 16 条
[1]  
BRUNSBACH BJ, 1993, P EPE 93, V6, P38
[2]  
Deng Xianming, 2009, IEEE IND APPL C IAS
[3]   Position-controlled synchronous reluctance motor without rotational transducer [J].
Ha, JI ;
Kang, SJ ;
Sul, SK .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1999, 35 (06) :1393-1398
[4]   Sensorless field-orientation control of an induction machine by high-frequency signal injection [J].
Ha, JI ;
Sul, SK .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1999, 35 (01) :45-51
[5]   Zero-speed tacholess LM torque control: Simply a matter of stator voltage integration [J].
Hurst, KD ;
Habetler, TG ;
Griva, G ;
Profumo, F .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1998, 34 (04) :790-795
[6]   TRANSDUCERLESS POSITION AND VELOCITY ESTIMATION IN INDUCTION AND SALIENT AC MACHINES [J].
JANSEN, PL ;
LORENZ, RD .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1995, 31 (02) :240-247
[7]  
KIM JM, 1997, IEEE APEC 97, V2, P743
[8]  
Kim JS, 1995, IEEE IND APPLIC SOC, P75, DOI 10.1109/IAS.1995.530286
[9]  
KIM JS, 1994, P 9 ANN APPL POW EL, V1, P363
[10]   A NOVEL POSITION SENSOR ELIMINATION TECHNIQUE FOR THE INTERIOR PERMANENT-MAGNET SYNCHRONOUS MOTOR DRIVE [J].
KULKARNI, AB ;
EHSANI, M .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1992, 28 (01) :144-150