Bienzyme biosensors for glucose, ethanol and putrescine built on oxidase and sweet potato peroxidase

被引:47
作者
Castillo, J
Gáspár, S
Sakharov, I
Csöregi, E
机构
[1] Lund Univ, Dept Biotechnol, SE-21100 Lund, Sweden
[2] Moscow MV Lomonosov State Univ, Fac Chem, Dept Chem Enzymol, Moscow 119899, Russia
关键词
amperometric biosensor; bienzyme electrode; redox hydrogel; sweet potato peroxidase;
D O I
10.1016/S0956-5663(03)00011-3
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Amperometric biosensors for glucose, ethanol, and biogenic amines (putrescine) were constructed using oxidase/peroxidase bienzyme systems. The H(2)O(2) produced by the oxidase in reaction with its substrate is converted into a measurable signal via a novel peroxidase purified from sweet potato peels. All developed biosensors are based on redox hydrogels formed of oxidases (glucose oxidase, alcohol oxidase, or amine oxidase) and the newly purified sweet potato peroxidase (SPP) cross-linked to a redox polymer. The developed electrodes were characterized (sensitivity, stability, and performances in organic medium) and compared with similarly built ones using the 'classical' horseradish peroxidase (HRP). The SPP-based electrodes displayed higher sensitivity and better detection limit for putrescine than those using HRP and were also shown to retain their activity in organic phase much better than the HPR based ones. The importance of attractive or repulsive electrostatic interactions between the peroxidases and oxidases (determined by their isoelectric points) were found to play an important role in the sensitivity of the obtained sensors. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:705 / 714
页数:10
相关论文
共 54 条
  • [1] ENZYMATIC DETERMINATION OF GLUCOSE IN A FLOW SYSTEM BY CATALYTIC-OXIDATION OF THE NICOTINAMIDE COENZYME AT A MODIFIED ELECTRODE
    APPELQVIST, R
    MARKOVARGA, G
    GORTON, L
    TORSTENSSON, A
    JOHANSSON, G
    [J]. ANALYTICA CHIMICA ACTA, 1985, 169 (MAR) : 237 - 247
  • [2] THIN-FILM BIENZYME AMPEROMETRIC BIOSENSORS BASED ON POLYMERIC REDOX MEDIATORS WITH ELECTROSTATIC BIPOLAR PROTECTING LAYER
    BOGUSLAVSKY, L
    KALASH, H
    XU, Z
    BECKLES, D
    GENG, L
    SKOTHEIM, T
    LAURINAVICIUS, V
    LEE, HS
    [J]. ANALYTICA CHIMICA ACTA, 1995, 311 (01) : 15 - 21
  • [3] BIOSENSORS FOR PROCESS-CONTROL
    BROOKS, SL
    HIGGINS, IJ
    NEWMAN, JD
    TURNER, APF
    [J]. ENZYME AND MICROBIAL TECHNOLOGY, 1991, 13 (12) : 946 - 955
  • [4] Carrea G, 2000, ANGEW CHEM INT EDIT, V39, P2226
  • [5] Cass A. E. G., 1990, BIOSENSORS PRACTICAL
  • [6] Purification and substrate specificity of peroxidase from sweet potato tubers
    Leon, JC
    Alpeeva, IS
    Chubar, TA
    Galaev, IY
    Csoregi, E
    Sakharov, IY
    [J]. PLANT SCIENCE, 2002, 163 (05) : 1011 - 1019
  • [7] Collins A, 2001, ELECTROANAL, V13, P425, DOI 10.1002/1521-4109(200104)13:6<425::AID-ELAN425>3.0.CO
  • [8] 2-5
  • [9] Cowell DC, 2001, ENVIR SCI R, V56, P157
  • [10] CARBON-FIBERS AS ELECTRODE MATERIALS FOR THE CONSTRUCTION OF PEROXIDASE-MODIFIED AMPEROMETRIC BIOSENSORS
    CSOREGI, E
    GORTON, L
    MARKOVARGA, G
    [J]. ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) : 59 - 70