Design methodology and area sensitivity analysis of horizontal subsurface flow constructed wetlands

被引:14
作者
Economopoulou, MA [1 ]
Tsihrintzis, VA [1 ]
机构
[1] Democritus Univ Thrace, Dept Environm Engn, Lab Ecol Engn & Technol, GR-67100 Xanthi, Greece
关键词
BOD removal; design methodology; nutrient removal; pathogen removal; seasonal performance; sensitivity analysis; subsurface flow constructed wetlands; unit area requirement; wastewater treatment;
D O I
10.1023/A:1023615324178
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An approach is presented to satisfy the demand for simple criteria, guidelines and models for the preliminary sizing of horizontal subsurface flow ( SF) constructed wetland systems. This approach eliminates time-consuming calculations and iterations by providing graphical solutions for wetland system sizing. Therefore, it can be used for the preliminary assessment of new or performance evaluation of existing subsurface flow constructed wetland systems. The validity of this methodology is checked with data from existing systems and is found to be quite satisfactory. This methodology is combined with simple equations predicting the maximum wetland capacity in summer, so as to assist designers in sizing installations in tourist areas with increased summer populations. Furthermore, based on this methodology, a sensitivity analysis is performed of the area requirements for wastewaters of various strengths and various design conditions and performance criteria. The results provide a useful overview to engineers and further simplify the design methodology of new subsurface flow constructed wetland systems.
引用
收藏
页码:147 / 174
页数:28
相关论文
共 31 条
[1]   Performance of a subsurface constructed wetland in Iran [J].
Badkoubi, A ;
Ganjidoust, H ;
Ghaderi, A ;
Rajabi, A .
WATER SCIENCE AND TECHNOLOGY, 1998, 38 (01) :345-350
[2]   Modeling BOD removal in constructed wetlands with mixing cell method [J].
Chen, SL ;
Wang, GT ;
Xue, SK .
JOURNAL OF ENVIRONMENTAL ENGINEERING, 1999, 125 (01) :64-71
[3]   A review of the design and performance of vertical-flow and hybrid reed bed treatment systems [J].
Cooper, P .
WATER SCIENCE AND TECHNOLOGY, 1999, 40 (03) :1-9
[4]   Implementation of constructed wetlands in developing countries [J].
Denny, P .
WATER SCIENCE AND TECHNOLOGY, 1997, 35 (05) :27-34
[5]  
Denny P., 1991, P115
[6]  
FISHER PJ, 1991, P C CONSTR WETL WAT, P21
[8]   Constructed wetlands in Queensland: Performance efficiency and nutrient bioaccumulation [J].
Greenway, M ;
Woolley, A .
ECOLOGICAL ENGINEERING, 1999, 12 (1-2) :39-55
[9]   Constructed wetlands: A chance to solve wastewater problems in developing countries [J].
Haberl, R .
WATER SCIENCE AND TECHNOLOGY, 1999, 40 (03) :11-17
[10]   Nitrogen removal in constructed wetlands employed to treat domestic wastewater [J].
Huang, J ;
Reneau, RB ;
Hagedorn, C .