Methods for shot-to-shot normalization in laser ablation with an inductively coupled plasma time-of-flight mass spectrometer

被引:61
作者
Leach, AM [1 ]
Hieftje, GM [1 ]
机构
[1] Indiana Univ, Dept Chem, Bloomington, IN 47405 USA
关键词
D O I
10.1039/b001968m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Single-shot laser ablation (one laser pulse per analysis) combined with inductively coupled plasma mass spectrometry offers tremendous potential for the direct elemental analysis of solid samples with high spatial resolution. However, the precision of the method is usually limited by variations in the laser irradiance and in the specimen being sampled. In this study, two data analysis techniques were evaluated to improve single-shot measurement precision. Both methods exploit the simultaneous full-spectrum acquisition capability of a time-of-flight mass spectrometer. In the first approach, a normalization factor is computed from the summed signal generated by all sample constituents, the reasoning being that the summed spectrum should be proportional to the total mass of sample ablated. This scheme results in a greater than factor of two improvement in precision, moderately better than is possible with a single internal standard. The enhancement in measurement precision was found to be concentration dependent, with the greatest improvement (10-50 fold) experienced by high concentration elements. The second method correlates the attenuation of plasma matrix ions to analyte intensities. The attenuation technique demonstrated no statistically significant improvement in precision, limited by the relatively low signal-to-noise ratio of the attenuated signals.
引用
收藏
页码:1121 / 1124
页数:4
相关论文
共 20 条
[1]   Investigation of light scattering for normalization of signals in laser ablation inductively coupled plasma mass spectrometry [J].
Baker, SA ;
Smith, BW ;
Winefordner, JD .
APPLIED SPECTROSCOPY, 1998, 52 (01) :154-160
[2]   ACOUSTIC-SIGNAL AS AN INTERNAL STANDARD FOR QUANTITATION IN LASER-GENERATED PLUMES [J].
CHEN, GY ;
YEUNG, ES .
ANALYTICAL CHEMISTRY, 1988, 60 (20) :2258-2263
[3]   Inter-element fractionation and correction in laser ablation inductively coupled plasma mass spectrometry [J].
Chen, ZX .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (12) :1823-1828
[4]   FRACTIONATION EFFECTS IN LASER-ABLATION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
CROMWELL, EF ;
ARROWSMITH, P .
APPLIED SPECTROSCOPY, 1995, 49 (11) :1652-1660
[5]   LASER SOLID SAMPLING FOR INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
DENOYER, ER ;
FREDEEN, KJ ;
HAGER, JW .
ANALYTICAL CHEMISTRY, 1991, 63 (08) :A445-&
[6]   Elemental fractionation of glass using laser ablation inductively coupled plasma mass spectrometry [J].
Figg, D ;
Kahr, MS .
APPLIED SPECTROSCOPY, 1997, 51 (08) :1185-1192
[7]   More investigations into elemental fractionation resulting from laser ablation inductively coupled plasma mass spectrometry on glass samples [J].
Figg, DJ ;
Cross, JB ;
Brink, C .
APPLIED SURFACE SCIENCE, 1998, 127 :287-291
[8]   Is laser-ablation-ICP-MS an alternative to solution analysis of solid samples? [J].
Hoffmann, E ;
Ludke, C ;
Scholze, H .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 359 (4-5) :394-398
[9]   MASS-SPECTROMETRY ON THE CHROMATOGRAPHIC TIME SCALE - REALISTIC EXPECTATIONS [J].
HOLLAND, JF ;
ENKE, CG ;
ALLISON, J ;
STULTS, JT ;
PINKSTON, JD ;
NEWCOME, B ;
WATSON, JT .
ANALYTICAL CHEMISTRY, 1983, 55 (09) :A997-&
[10]   Characterization of acoustic signals produced by ultraviolet laser ablation inductively coupled plasma atomic emission spectrometry [J].
Kanicky, V ;
Otruba, V ;
Mermet, JM .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 363 (04) :339-346