Dynamic functional imaging of relative cerebral blood volume during rat forepaw stimulation

被引:446
作者
Mandeville, JB
Marota, JJA
Kosofsky, BE
Keltner, JR
Weissleder, R
Rosen, BR
Weisskoff, RM
机构
[1] Massachusetts Gen Hosp, NMR Ctr, Charlestown, MA 02129 USA
[2] Massachusetts Gen Hosp, Dept Radiol, Charlestown, MA 02129 USA
[3] Massachusetts Gen Hosp, Dept Anesthesiol, Charlestown, MA 02129 USA
[4] Massachusetts Gen Hosp, Dept Neurol, Charlestown, MA 02129 USA
[5] Massachusetts Gen Hosp, Ctr Mol Imaging Res, Charlestown, MA 02129 USA
关键词
fMRI; CBV; rat; contrast agent;
D O I
10.1002/mrm.1910390415
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dynamic measurements of regional changes in cerebral blood volume (CBV) were performed in rat models of hypercarbia and focal neuronal activation using T-2-weighted imaging after injection of an intravascular contrast agent with a very long blood half-life. Calculated percent CBV change during hypercarbia was consistent with literature results from other noninvasive modalities. Equivalent percent CBV increases were found using spin-and gradient-echo images, suggesting proportional changes in blood volume for capillaries and small veins. During electrical stimulation of rat forepaw, focal CBV response to stimulation (24 +/- 4%) was significantly delayed relative to blood oxygen level dependent (BOLD) signal after both onset and cessation of stimulation. Poststimulus CBV decay was temporally consistent with the BOLD poststimulus undershoot. The use of exogenous agent increased the functional contrast-to-noise ratio relative to BOLD imaging by 5.7 +/- 1.3 at a magnetic field strength of 2 Tesla and 1.5 +/- 0.2 at 4.7 Tesla.
引用
收藏
页码:615 / 624
页数:10
相关论文
共 45 条
[1]   TIME COURSE EPI OF HUMAN BRAIN-FUNCTION DURING TASK ACTIVATION [J].
BANDETTINI, PA ;
WONG, EC ;
HINKS, RS ;
TIKOFSKY, RS ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (02) :390-397
[2]   FUNCTIONAL CEREBRAL IMAGING BY SUSCEPTIBILITY-CONTRAST NMR [J].
BELLIVEAU, JW ;
ROSEN, BR ;
KANTOR, HL ;
RZEDZIAN, RR ;
KENNEDY, DN ;
MCKINSTRY, RC ;
VEVEA, JM ;
COHEN, MS ;
PYKETT, IL ;
BRADY, TJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (03) :538-546
[3]   FUNCTIONAL MAPPING OF THE HUMAN VISUAL-CORTEX BY MAGNETIC-RESONANCE-IMAGING [J].
BELLIVEAU, JW ;
KENNEDY, DN ;
MCKINSTRY, RC ;
BUCHBINDER, BR ;
WEISSKOFF, RM ;
COHEN, MS ;
VEVEA, JM ;
BRADY, TJ ;
ROSEN, BR .
SCIENCE, 1991, 254 (5032) :716-719
[4]   MR CONTRAST DUE TO INTRAVASCULAR MAGNETIC-SUSCEPTIBILITY PERTURBATIONS [J].
BOXERMAN, JL ;
HAMBERG, LM ;
ROSEN, BR ;
WEISSKOFF, RM .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) :555-566
[5]   PROTON NUCLEAR MAGNETIC-RESONANCE IMAGING OF REGIONALLY ISCHEMIC CANINE HEARTS - EFFECT OF PARAMAGNETIC PROTON SIGNAL ENHANCEMENT [J].
BRADY, TJ ;
GOLDMAN, MR ;
PYKETT, IL ;
BUONANNO, FS ;
KISTLER, JP ;
NEWHOUSE, JH ;
BURT, CT ;
HINSHAW, WS ;
POHOST, GM .
RADIOLOGY, 1982, 144 (02) :343-347
[6]  
Dale AM, 1997, HUM BRAIN MAPP, V5, P329, DOI 10.1002/(SICI)1097-0193(1997)5:5<329::AID-HBM1>3.0.CO
[7]  
2-5
[8]  
DENNIE J, 1997, P ISMRM 5 ANN M VANC, P489
[9]   PERFUSION IMAGING [J].
DETRE, JA ;
LEIGH, JS ;
WILLIAMS, DS ;
KORETSKY, AP .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :37-45
[10]   Improving MR quantification of regional blood volume with intravascular T-1 contrast agents: Accuracy, precision, and water exchange [J].
Donahue, KM ;
Weisskoff, RM ;
Chesler, DA ;
Kwong, KK ;
Bogdanov, AA ;
Mandeville, JB ;
Rosen, BR .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :858-867