Determination of the purity of acidimetric standards by constant-current coulometry, and the intercomparison between CRMs

被引:8
作者
Asakai, Toshiaki
Murayama, Mariko
Tanaka, Tatsuhiko
机构
[1] Natl Inst Technol & Evaluat, Shibuya Ku, Tokyo 1510066, Japan
[2] Tokyo Univ Sci, Fac Engn, Shinjuku Ku, Tokyo 1628601, Japan
关键词
coulometry (constant-current); stoichiometric standards; potassium hydrogen phthalate; amidosulfuric acid;
D O I
10.1007/s00769-006-0203-z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The accuracy and uncertainty of the coulometric measurement results of reference materials for acidimetric titration were examined in this study. The results for amidosulfuric acid and potassium hydrogen phthalate are presented. The uncertainty was investigated by examining the dependency on the sample size and on the electrolysis current. Changes in the titration parameters did not result in any significant effects on the titration results. Acidimetric standards with the certified value linked to the SI were developed. In addition, the intercomparison of acidimetric standards was carried out by gravimetric titration, and the relationship between our coulometric results was determined. Furthermore, due to recent internationalization, not only the traceability to the SI but also the relationship and consistency of their analytical data have gained increasing importance. Our results were validated using certified reference materials (CRMs) obtained from different National Metrology Institutes (NMIs), and their relationships are presented.
引用
收藏
页码:151 / 155
页数:5
相关论文
共 12 条
[1]  
[Anonymous], 1967, ANALYST, V92, P587
[2]   Evaluation of certified reference materials for oxidation-reduction titration by precise coulometric titration and volumetric analysis [J].
Asakai, T ;
Kakihara, Y ;
Kozuka, Y ;
Hossaka, S ;
Murayama, M ;
Tanaka, T .
ANALYTICA CHIMICA ACTA, 2006, 567 (02) :269-276
[3]   Investigation of the drying conditions for amidosulfuric acid [J].
Asakai, T ;
Minegishi, R ;
Inaba, N ;
Ishimura, Y ;
Murayama, M ;
Tanaka, T .
ANALYTICAL SCIENCES, 2006, 22 (03) :461-463
[4]  
BREITENBACH M, 1988, METROLOGISCHE ABHAND, V8, P137
[5]   ACCURACY OF THE MEASUREMENT OF PURITY OF SULFAMIC ACID BY COULOMETRIC TITRATION [J].
HIOKI, A ;
KOKUBUN, A ;
KUBOTA, M .
ANALYST, 1994, 119 (08) :1879-1882
[6]  
*JAP IND STAND COM, 2006, 8005 JIS K JAP IND S
[7]   Link to the SI via primary direct methods [J].
Mariássy, M ;
Vyskocil, L ;
Mathiasová, A .
ACCREDITATION AND QUALITY ASSURANCE, 2000, 5 (10-11) :437-440
[8]   AUTOMATED, HIGH-PRECISION COULOMETRIC TITRIMETRY .2. STRONG AND WEAK ACIDS AND BASES [J].
PRATT, KW .
ANALYTICA CHIMICA ACTA, 1994, 289 (02) :135-142
[9]   PRECISE COULOMETRIC TITRATION OF ACIDS AND BASES [J].
TAYLOR, JK ;
SMITH, SW .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS SECTION A-PHYSICS AND CHEMISTRY, 1959, 63 (02) :153-159
[10]   PRECISE COULOMETRIC TITRATION OF THE POTASSIUM HYDROGEN PHTHALATE (NBS-SRM 84D) - USE OF THE FARADAY CONSTANT AS AN INTERNATIONAL STANDARD [J].
YOSHIMORI, T ;
TANAKA, T .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1979, 52 (05) :1366-1367