Engineering of fibrin-based functional and implantable small-diameter blood vessels

被引:198
作者
Swartz, DD [1 ]
Russell, JA [1 ]
Andreadis, ST [1 ]
机构
[1] SUNY Buffalo, Dept Chem & Biol Engn, Bioengn Lab, Dept Chem & Biol, Buffalo, NY 14260 USA
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 2005年 / 288卷 / 03期
关键词
matrix degradation/remodeling; vascular disease; vascular reactivity; vascular tissue engineering; smooth muscle; endothelial cells;
D O I
10.1152/ajpheart.00479.2004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We engineered implantable small-diameter blood vessels based on ovine smooth muscle and endothelial cells embedded in fibrin gels. Cylindrical tissue constructs remodeled the fibrin matrix and exhibited considerable reactivity in response to receptor- and nonreceptor-mediated vasoconstrictors and dilators. Aprotinin, a protease inhibitor of fibrinolysis, was added at varying concentrations and affected the development and functionality of tissue-engineered blood vessels (TEVs) in a concentration-dependent manner. Interestingly, at moderate concentrations, aprotinin increased mechanical strength but decreased vascular reactivity, indicating a possible relationship between matrix degradation/ remodeling, vasoreactivity, and mechanical properties. TEVs developed considerable mechanical strength to withstand interpositional implantation in jugular veins of lambs. Implanted TEVs integrated well with the native vessel and demonstrated patency and similar blood flow rates as the native vessels. At 15 wk postimplantation, TEVs exhibited remarkable matrix remodeling with production of collagen and elastin fibers and orientation of smooth muscle cells perpendicular to the direction of blood flow. Implanted vessels gained significant mechanical strength and reactivity that were comparable to those of native veins. Our work demonstrates that fibrin-based TEVs hold significant promise for treatment of vascular disease and as a biological model for studying vascular development and pathophysiology.
引用
收藏
页码:H1451 / H1460
页数:10
相关论文
共 38 条
[1]  
Bader A, 2000, TRANSPLANTATION, V70, P7
[2]   Engineered alignment in media equivalents: Magnetic prealignment and Mandrel compaction [J].
Barocas, VH ;
Girton, TS ;
Tranquillo, RT .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (05) :660-666
[3]   A biological hybrid model for collagen-based tissue engineered vascular constructs [J].
Berglund, JD ;
Mohseni, MM ;
Nerem, RM ;
Sambanis, A .
BIOMATERIALS, 2003, 24 (07) :1241-1254
[4]   NEW ARTIFICIAL CONNECTIVE MATRIX-LIKE STRUCTURE - THROMBOGENICITY AND USE AS ENDOTHELIAL-CELL CULTURE SUPPORT [J].
BORDENAVE, L ;
LEFEBVRE, F ;
BAREILLE, R ;
ROUAIS, F ;
BAQUEY, C ;
RABAUD, M .
BIOMATERIALS, 1992, 13 (07) :439-447
[5]   STIMULATION OF MIGRATION OF HUMAN AORTIC SMOOTH-MUSCLE CELLS BY VITRONECTIN - IMPLICATIONS FOR ATHEROSCLEROSIS [J].
BROWN, SL ;
LUNDGREN, CH ;
NORDT, T ;
FUJII, S .
CARDIOVASCULAR RESEARCH, 1994, 28 (12) :1815-1820
[6]  
CLARK RAF, 1995, J CELL SCI, V108, P1251
[7]   Properties of engineered vascular constructs made from collagen, fibrin, and collagen-fibrin mixtures [J].
Cummings, CL ;
Gawlitta, D ;
Nerem, RM ;
Stegemann, JP .
BIOMATERIALS, 2004, 25 (17) :3699-3706
[8]   Clinical autologous in vitro endothelialization of infrainguinal ePTFE grafts in 100 patients: A 9-year experience [J].
Deutsch, M ;
Meinhart, J ;
Fischlein, T ;
Preiss, P ;
Zilla, P .
SURGERY, 1999, 126 (05) :847-855
[9]  
Drury J K, 1987, Ann Vasc Surg, V1, P542, DOI 10.1016/S0890-5096(06)61437-4
[10]  
DVORAK HF, 1987, LAB INVEST, V57, P673