Impedance characterization of a piezoelectric immunosensor Part I: Antibody coating and buffer solution

被引:11
作者
Kim, GH
Rand, AG
Letcher, SV [1 ]
机构
[1] Univ Rhode Isl, Dept Phys, Kingston, RI 02881 USA
[2] Univ Rhode Isl, Dept Food Sci & Nutr, Kingston, RI 02881 USA
关键词
impedance analyzer; AT-cut quartz crystal; equivalent circuit analysis; potassium phosphate buffer; antibody layer;
D O I
10.1016/S0956-5663(02)00142-2
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This study investigated the impedance characteristics of a 5 MHz quartz crystal resonator oscillating in a thickness-shear mode for utilization as a biosensor. An impedance analyzer measured the impedance of the quartz crystal, which determined all mechanical properties of the oscillating quartz and its immediate environment. In this study, the impedance behavior of the oscillating crystal was characterized in air, in potassium phosphate buffer solution, and with immobilization of antibodies using protein-A. The potassium phosphate buffer behaved like a Newtonian liquid. The series resonance frequency shifted down about 900 Hz on contact with the buffer. An immobilized-antibody layer on the quartz surface behaved like a rigid mass when immersed in the buffer solution. The impedance curve following immobilization of antibodies was shifted down in frequency by about 200 Hz compared with its value when the bare crystal was immersed in the buffer solution. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:83 / 89
页数:7
相关论文
共 16 条
[1]   Evaluation of antibody immobilization methods for piezoelectric biosensor application [J].
Babacan, S ;
Pivarnik, P ;
Letcher, S ;
Rand, AG .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (11-12) :615-621
[2]  
Bottom V.E., 1982, INTRO QUARTZ CRYSTAL
[3]   MOLECULAR SLIP AT THE SOLID-LIQUID INTERFACE OF AN ACOUSTIC-WAVE SENSOR [J].
FERRANTE, F ;
KIPLING, AL ;
THOMPSON, M .
JOURNAL OF APPLIED PHYSICS, 1994, 76 (06) :3448-3462
[4]   CHARACTERIZATION OF A THICKNESS-SHEAR MODE QUARTZ RESONATOR WITH MULTIPLE NONPIEZOELECTRIC LAYERS [J].
GRANSTAFF, VE ;
MARTIN, SJ .
JOURNAL OF APPLIED PHYSICS, 1994, 75 (03) :1319-1329
[5]   Investigation of highly sensitive piezoelectric immunosensors for 2,4-dichlorophenoxyacetic acid [J].
Halámek, J ;
Hepel, M ;
Skládal, P .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (4-5) :253-260
[6]   A transverse shear model of a piezoelectric chemical sensor [J].
Hayward, GL ;
Thompson, M .
JOURNAL OF APPLIED PHYSICS, 1998, 83 (04) :2194-2201
[7]  
KANAZAWA KK, 1985, ANAL CHIM ACTA, V175, P99
[8]  
KOSSLINGER C, 1992, BIOSENS BIOELECTRON, V7, P411
[9]   OPERATION OF AN ULTRASENSITIVE 30-MHZ QUARTZ-CRYSTAL MICROBALANCE IN LIQUIDS [J].
LIN, ZX ;
YIP, CM ;
JOSEPH, IS ;
WARD, MD .
ANALYTICAL CHEMISTRY, 1993, 65 (11) :1546-1551
[10]   CHARACTERIZATION OF A QUARTZ CRYSTAL MICROBALANCE WITH SIMULTANEOUS MASS AND LIQUID LOADING [J].
MARTIN, SJ ;
GRANSTAFF, VE ;
FRYE, GC .
ANALYTICAL CHEMISTRY, 1991, 63 (20) :2272-2281