Muscle sizes and moment arms of rotator cuff muscles determined by magnetic resonance imaging

被引:62
作者
Juul-Kristensen, B
Bojsen-Moller, F
Finsen, L
Eriksson, J
Johansson, G
Ståhlberg, F
Ekdahl, C
机构
[1] Natl Inst Occupat Hlth, Dept Physiol, DK-2100 Copenhagen, Denmark
[2] Univ Copenhagen, Dept Funct Anat & Biomech, Copenhagen, Denmark
[3] Lund Inst Technol, Dept Work Environm, Lund, Sweden
[4] Univ Lund Hosp, Dept Diagnost Radiol, S-22185 Lund, Sweden
[5] Lund Univ, Dept Phys Therapy, Lund, Sweden
关键词
rotator cuff muscles; moment arms; muscle size; magnetic resonance imaging; anthropometry;
D O I
10.1159/000016784
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
Biomechanical models which require information on, e.g., joint torque and muscle force are useful in the estimation of when and how mechanical overload of the musculoskeletal system may lead to disorders. The aim was to study the reliability and validity of magnetic resonance imaging (MRI) to quantify muscle sizes and moment arms by MRI and to test selected anthropometric measures as predictors of muscle sizes and moment arms. A total of 20 healthy Scandinavian women (age 22-58 years) participated in an MRI scanning of their dominant shoulder. With a PC-based program the reliability and the validity of the MRI measurements was estimated to be high, and mean anatomical cross-sectional areas (ACSA) and muscle lengths were measured to be 4.0, 9.8 and 12.1 cm(2) and 12.0, 12.6 and 12.8 cm for m. supraspinatus, m. infraspinatus and m. subscapularis, respectively. Volumes were calculated to be 48.8, 125.1 and 153.6 cm(3). Moment arms were measured with the upper arm in a neutral position and in a functional position of 34 degrees abduction for m. supraspinatus only, and were 2.4 and 2.6 cm. Physiological cross-sectional area (PCSA) and its fiber force component were estimated from dissected fiber length and pennation angle. MRI volume and PCSA were 1.4-1.7 times higher than dissection data, primarily because of age differences, No external anthropometric measures were found to be predictors of volumes or moment arms. Copyright (C) 2000 S. Karger AG. Basel.
引用
收藏
页码:214 / 222
页数:9
相关论文
共 29 条
[1]  
[Anonymous], 1986, INT J IND ERGONOM, DOI [10.1016/0169-8141(86)90006-5, DOI 10.1016/0169-8141(86)90006-5]
[2]   GLENOHUMERAL MUSCLE FORCE AND MOMENT MECHANICS IN A POSITION OF SHOULDER INSTABILITY [J].
BASSETT, RW ;
BROWNE, AO ;
MORREY, BF ;
AN, KN .
JOURNAL OF BIOMECHANICS, 1990, 23 (05) :405-&
[3]   RELATIVE TENSION AND POTENTIAL EXCURSION OF MUSCLES IN THE FOREARM AND HAND [J].
BRAND, PW ;
THOMPSON, DE .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1981, 6 (03) :209-219
[4]   PREVALENCE OF SHOULDER AND UPPER-LIMB DISORDERS AMONG WORKERS IN THE FISH-PROCESSING INDUSTRY [J].
CHIANG, HC ;
KO, YC ;
CHEN, SS ;
YU, HS ;
WU, TN ;
CHANG, PY .
SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1993, 19 (02) :126-131
[5]  
CUTTS A, 1988, J ANAT, V160, P75
[6]  
DRAGONI S, 1994, J SPORT MED PHYS FIT, V34, P407
[7]  
EDGERTON VR, 1986, BIOCH EXERCISE 6, V16, P487
[8]  
ERIKSSON J, 1998, THESIS LUND U LUND
[9]  
HANSEN K, 1998, 7 NAT I OCC HLTH, P35
[10]   CHANGES IN PENNATION WITH JOINT ANGLE AND MUSCLE TORQUE - IN-VIVO MEASUREMENTS IN HUMAN BRACHIALIS MUSCLE [J].
HERBERT, RD ;
GANDEVIA, SC .
JOURNAL OF PHYSIOLOGY-LONDON, 1995, 484 (02) :523-532