Leg length measurement: a new method to assure the correct leg length in total hip arthroplasty

被引:14
作者
Affatato, S
Toni, A
机构
[1] Ist Ortoped Rizzoli, Lab Tecnol Med, I-40136 Bologna, Italy
[2] Ist Ortoped Rizzoli, Div Ortoped & Traumatol 1, I-40136 Bologna, Italy
关键词
ultrasound; non-invasive method; leg length;
D O I
10.1016/S1350-4533(00)00058-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
The precise measurement of leg length plays an important role in total hip arthroplasty. Leg length inequality occurs frequently after total hip arthroplasty and may cause patient discomfort. Current clinical methods used for measuring leg length are not accurate enough to meet the demands of precision required for hip replacement. The aim of this study was to examine the validity of determining leg length differences using an ultrasound system, The proposed system measures the distance between three points, in millimetres, so that the difference between preoperative and postoperative measurements gives an indication about the leg length. The mean ultrasound variation observed in in vitro measurements showed a relative error of 1.7% (range: 52-133 mm) that means a leg length inequality of about 0.4 mm (range: 52-133 mm). The method is non-invasive (ultrasound is not limited by radiation hazards), easy, quick to use, and can be used for standard clinical screening. (C) 2000 IPEM. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:435 / 439
页数:5
相关论文
共 24 条
[1]
Bal B S, 1996, Am J Orthop (Belle Mead NJ), V25, P61
[2]
Charnley J., 1979, LOW FRICTION ARTHROP
[3]
CLARK GR, 1972, RHEUMATOL PHYS MED, V1, P385
[4]
Mechanical validation of whole bone composite femur models [J].
Cristofolini, L ;
Viceconti, M ;
Cappello, A ;
Toni, A .
JOURNAL OF BIOMECHANICS, 1996, 29 (04) :525-535
[5]
Effect of superior and superolateral relocations of the hip center on hip joint forces - An experimental and analytical analysis [J].
Doehring, TC ;
Rubash, HE ;
Shelley, FJ ;
Schwendeman, LJ ;
Donaldson, TK ;
Navalgund, YA .
JOURNAL OF ARTHROPLASTY, 1996, 11 (06) :693-703
[6]
Edeen J, 1995, Am J Orthop (Belle Mead NJ), V24, P347
[7]
Trochanteric transfer in total hip replacement: Effects on the moment arms and force-generating capacities of the hip abductors [J].
Free, SA ;
Delp, SL .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1996, 14 (02) :245-250
[8]
Friberg O, 1988, Int Disabil Stud, V10, P49
[9]
THE RELATIONSHIP BETWEEN LEG LENGTH DISCREPANCY AND LUMBAR FACET ORIENTATION [J].
FROH, R ;
YONGHING, K ;
CASSIDY, JD ;
HOUSTON, CS .
SPINE, 1988, 13 (03) :325-327
[10]
HERBERT D, 1997, ORTHOPEDICS, V20, P331