Laser-assisted neuroendoscopy using a neodymium-yttrium aluminum garnet or diode contact laser with pretreated fiber tips

被引:61
作者
Vandertop, WP
Verdaasdonk, RM
van Swol, CFP
机构
[1] Univ Utrecht Hosp, Dept Neurosurg, NL-3508 GA Utrecht, Netherlands
[2] Univ Utrecht Hosp, Dept Clin Technol & Phys, Utrecht, Netherlands
[3] Wilhelmina Childrens Hosp, Utrecht, Netherlands
关键词
neurosurgical endoscopy; endoscopic surgery; laser surgery; diode laser; Nd-YAG laser; laser fiber tips; contact laser;
D O I
10.3171/jns.1998.88.1.0082
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Although lasers have proved to be valuable in neuroendoscopy, surgeons are still not comfortable using high-energy laser endoscopic probes in proximity to vital structures such as the basilar artery in third ventriculostomy. The authors have developed a special laser catheter for use in neuroendoscopy; the object of this paper is to present their experimental and clinical experiences using the catheter. Methods. This laser catheter is fitted with an atraumatic ball-shaped fiber tip that is pretreated with a layer of carbon particles. These carbon particles absorb approximately 90% of the energy emitted, which is very effectively converted into heat. As the heat is generated in this very thin layer of carbon coating, the temperature at the surface of the ball-shaped tip reaches ablative temperatures instantly at powers of only a few watts per second, which has enabled the authors to limit drastically the amount of laser light used and the length of exposure needed, thereby increasing safety even around critical structures. Conclusions. The authors present experimental data and their clinical experience using these pretreated fiber tips with a neodymium-yttrium aluminum garnet contact laser or a diode contact laser in 49 patients (22 males and 27 females) and a variety of procedures: third ventriculocisternostomy (33 patients), cyst fenestration (nine patients), colloid cyst resection (six patients). and fenestration of the septum pellucidum (one patient). There was no instance of mortality or increased morbidity. To date, the procedure success rate is 100% and the overall outcome success rate is 86%. The authors conclude that pretreated atraumutic ball-shaped fiber tips now make laser application safe and effective in a variety of neuroendoscopic procedures. Because of their low power range (only several watts). compact diode lasers will he the energy source of first choice.
引用
收藏
页码:82 / 92
页数:11
相关论文
共 24 条
[1]  
CRONE KR, 1992, NEUROENDOSCOPY, V1, P41
[2]   Percutaneous endoscopic treatment of suprasellar arachnoid cysts: Ventriculocystostomy or ventriculocystocisternostomy? Technical note [J].
Decq, P ;
Brugieres, P ;
LeGuerinel, C ;
Djindjian, M ;
Keravel, Y ;
Nguyen, JP .
JOURNAL OF NEUROSURGERY, 1996, 84 (04) :696-701
[3]   FLEXIBLE ENDOSCOPES IN TREATMENT OF COLLOID CYSTS OF THE 3RD VENTRICLE [J].
DEINSBERGER, W ;
BOKER, DK ;
SAMII, M .
MINIMALLY INVASIVE NEUROSURGERY, 1994, 37 (01) :12-16
[4]  
Drake J M, 1993, Neurosurg Clin N Am, V4, P657
[5]  
EHNI G, 1987, SURG 3 VENTRICLE, P326
[6]  
Grotenhuis JA, 1995, MANUAL ENDOSCOPIC PR, P12
[7]  
JONES RFC, 1995, MINIM INVASIV THER, P33
[8]  
Jones RFT, 1992, NEUROENDOSCOPY, P63
[9]   STEREOTAXIC MANAGEMENT OF COLLOID CYSTS - FACTORS PREDICTING SUCCESS [J].
KONDZIOLKA, D ;
LUNSFORD, LD .
JOURNAL OF NEUROSURGERY, 1991, 75 (01) :45-51
[10]   LASERS IN NEUROSURGERY [J].
KRISHNAMURTHY, S ;
POWERS, SK .
LASERS IN SURGERY AND MEDICINE, 1994, 15 (02) :126-167