Preconcentration of trace amounts of platinum in water on different sorbents

被引:14
作者
Godlewska-Zylkiewicz, B [1 ]
Lesniewska, B
Michalowski, J
Hulanicki, A
机构
[1] Univ Bialystok, Inst Chem, PL-15443 Bialystok, Poland
[2] Univ Warsaw, Dept Chem, PL-02093 Warsaw, Poland
关键词
platinum; preconcentration; solid phase extraction;
D O I
10.1080/03067319908047301
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three different sorbents for platinum preconcentration in water were investigated: alumina, silica gel with bonded aminopropyl groups and Cellex-T. The sorbents were tested in a microcolumn at the flow rate 3 ml/min. Elution was performed with 2.0 mol/l ammonia, 2.0 mol/l hydrochloric acid and 1.2 mol/l thiourea solution, respectively. The optimal enrichment factor was 400 for the alumina column, when the eluent volume was 25 mul Satisfactory precision was obtained for all sorbents. As the detection technique was used either FAAS or GFAAS, depending on the concentration of platinum in the eluate.
引用
收藏
页码:71 / 81
页数:11
相关论文
共 20 条
[1]   A contribution to the ecology and enology of platinum [J].
Alt, F ;
Eschnauer, HR ;
Mergler, B ;
Messerschmidt, J ;
Tolg, G .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (08) :1013-1019
[2]   PLATINUM TRACES IN AIRBORNE PARTICULATE MATTER - DETERMINATION OF WHOLE CONTENT, PARTICLE-SIZE DISTRIBUTION AND SOLUBLE PLATINUM [J].
ALT, F ;
BAMBAUER, A ;
HOPPSTOCK, K ;
MERGLER, B ;
TOLG, G .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 346 (6-9) :693-696
[3]   Analytical methods for the determination of platinum in biological and environmental materials [J].
Balcerzak, M .
ANALYST, 1997, 122 (05) :R67-R74
[4]   Determination of platinum at trace levels in environmental and biological materials [J].
Barefoot, RR .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1997, 31 (02) :309-314
[5]   APPLICATION OF CELLULOSE ANION-EXCHANGERS TO SEPARATION OF PALLADIUM FROM PLATINUM OR IRIDIUM WITH GLYCINE AS COMPLEXING AGENT AND ATOMIC-ABSORPTION SPECTROMETRY FOR DETECTION [J].
BRAJTER, K ;
SLONAWSKA, K .
TALANTA, 1983, 30 (07) :471-474
[6]   ONLINE PRECONCENTRATION AND DETERMINATION OF TRACE PLATINUM BY FLOW-INJECTION ATOMIC-ABSORPTION SPECTROMETRY [J].
CANTARERO, A ;
GOMEZ, MM ;
CAMARA, C ;
PALACIOS, MA .
ANALYTICA CHIMICA ACTA, 1994, 296 (02) :205-211
[7]   Preconcentration and matrix separation of precious metals in geological and related materials using metalfix-chelamine resin prior to inductively coupled plasma mass spectrometry [J].
Coedo, AG ;
Dorado, MT ;
Padilla, I ;
Alguacil, F .
ANALYTICA CHIMICA ACTA, 1997, 340 (1-3) :31-40
[8]   ONLINE PRECONCENTRATION AND SEPARATION OF PALLADIUM, PLATINUM AND IRIDIUM USING ALPHA-AMINO PYRIDINE RESIN WITH FLAME ATOMIC-ABSORPTION SPECTROMETRY [J].
DI, P ;
DAVEY, DE .
TALANTA, 1995, 42 (05) :685-692
[9]   THE SEPARATION OF PLATINUM, PALLADIUM AND GOLD FROM SILICATE ROCKS BY THE ANION-EXCHANGE SEPARATION OF CHLORO COMPLEXES AFTER A SODIUM PEROXIDE FUSION - AN INVESTIGATION OF LOW RECOVERIES [J].
ENZWEILER, J ;
POTTS, PJ .
TALANTA, 1995, 42 (10) :1411-1418
[10]  
Farago ME, 1996, FRESEN J ANAL CHEM, V354, P660