Performance comparison of CFCs with their substitutes using artificial neural network

被引:56
作者
Arcaklioglu, E [1 ]
机构
[1] Kirikkale Univ, Dept Mech Engn, Fac Engn, TR-71450 Kirikkale, Turkey
关键词
artificial neural networks; refrigerant mixtures; coefficient of performance; irreversibility; REFPROP;
D O I
10.1002/er.1020
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In order to decrease global pollution due to chlorofluorocarbons (CFCs), the usage of HFC- and HC-based refrigerants and their mixtures are considered instead of CFCs (R12, R22, and R502). This was confirmed by an international consensus (i.e. Montreal Protocol signed in 1987). This paper offers to determine coefficient of performance (COP) and total irreversibility (TI) values of vapour-compression refrigeration system with different refrigerants and their mixtures mentioned above using artificial neural networks (ANN). In order to train the network, COPs and TIs of refrigerants and their some binary, ternary and quartet mixtures of different ratios have been calculated in a vapour-compression refrigeration system with liquid/suction line heat exchanger. In the calculations thermodynamic properties of refrigerants have been taken from REFPROP 6.01 which was prepared based on Helmholtz energy equation of state. To achieve this, a new software has been written in FORTRAN programming language using sub-programs of REFPROP, and all related calculations have been performed using this software using constant temperature method as reference. Scaled conjugate gradient, Pola-Ribiere conjugate gradient, and Levenberg-Marquardt learning algorithms and logistic sigmoid transfer function were used in the network. Mixing ratios of refrigerants, and evaporator temperature were used as input layer; COP and TI values were used as output layer. It is shown that R-2 values are about 0.9999, maximum errors for training and test data are smaller than 2 and 3%, respectively. It is concluded that, ANNs can be used for prediction of COP and TI as an accurate method in the systems. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:1113 / 1125
页数:13
相关论文
共 17 条
[1]  
[Anonymous], EFFICIENCY COST OPTI
[2]   New approach to dynamic modelling of vapour-compression liquid chillers: artificial neural networks [J].
Bechtler, H ;
Browne, MW ;
Bansal, PK ;
Kecman, V .
APPLIED THERMAL ENGINEERING, 2001, 21 (09) :941-953
[3]   Experimental evaluation of refrigerant mixtures as substitutes for CFC12 and R502 [J].
Camporese, R ;
Bigolaro, G ;
Bobbo, S ;
Cortella, G .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1997, 20 (01) :22-31
[4]   Performance and heat transfer characteristics of hydrocarbon refrigerants in a heat pump system [J].
Chang, YS ;
Kim, MS ;
Ro, ST .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2000, 23 (03) :232-242
[5]   ROLE OF REFRIGERANT MIXTURES AS ALTERNATIVES TO CFCS [J].
DIDION, DA ;
BIVENS, DB .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1990, 13 (03) :163-175
[6]   Mixing rules for the specific heat capacities of several HFC-mixtures [J].
Gunther, D ;
Steimle, F .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1997, 20 (04) :235-243
[7]   PERFORMANCE SIMULATION OF SINGLE-EVAPORATOR DOMESTIC REFRIGERATORS CHARGED WITH PURE AND MIXED REFRIGERANTS [J].
JUNG, DS ;
RADERMACHER, R .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1991, 14 (04) :223-232
[8]   Artificial neural networks for modelling the starting-up of a solar steam-generator [J].
Kalogirou, SA ;
Neocleous, CC ;
Schizas, CN .
APPLIED ENERGY, 1998, 60 (02) :89-100
[9]   Artificial neural networks for the prediction of the energy consumption of a passive solar building [J].
Kalogirou, SA ;
Bojic, M .
ENERGY, 2000, 25 (05) :479-491
[10]   Modeling of solar domestic water heating systems using Artificial Neural Networks [J].
Kalogirou, SA ;
Panteliou, S ;
Dentsoras, A .
SOLAR ENERGY, 1999, 65 (06) :335-342