The performance of a novel sensor based on an integrated optical (IO) disk microcavity (MC) is theoretically studied. The MC is a resonant waveguide structure in which multiple interference of a guided mode occurs. At resonance, the MC is extremely sensitive to refractive index changes and it sustains locally enhanced optical field. Therefore, the MC is naturally suitable as an extremely responsive sensor for measuring minute changes in refractive index and/or fluorescence of an analyte. Combination of multiple interference and extremely small sampling volume (few femtoliters) provides unique sensitivity of the MC device. A factor of 9 increase in fluorescence sensitivity versus waveguide sensor is anticipated. Provided shot-noise limited detection, the refractive index resolution down to 10(-9) is feasible with the MC sensor, which exceeds that of the straight waveguide interferometer by the order of magnitude. MC-sensors can be combined into arrays providing high throughput detection of both labeled and non-fluorescent biological species. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:58 / 67
页数:10
相关论文
共 28 条
[1]   Compact microring notch filters [J].
Absil, PP ;
Hryniewicz, JV ;
Little, BE ;
Wilson, RA ;
Joneckis, LG ;
Ho, PT .
IEEE PHOTONICS TECHNOLOGY LETTERS, 2000, 12 (04) :398-400
[2]   SENSITIVITY ENHANCEMENT OF OPTICAL IMMUNOSENSORS BY THE USE OF A SURFACE-PLASMON RESONANCE FLUOROIMMUNOASSAY [J].
ATTRIDGE, JW ;
DANIELS, PB ;
DEACON, JK ;
ROBINSON, GA ;
DAVIDSON, GP .
BIOSENSORS & BIOELECTRONICS, 1991, 6 (03) :201-214
[3]   Resonant-enhanced evanescent-wave fluorescence biosensing with cylindrical optical cavities [J].
Blair, S ;
Chen, Y .
APPLIED OPTICS, 2001, 40 (04) :570-582
[4]   A single channel dropping filter based on a cylindrical microresonator [J].
Blom, FC ;
Kelderman, H ;
Hoekstra, HJWM ;
Driessen, A ;
Popma, TJA ;
Chu, ST ;
Little, BE .
OPTICS COMMUNICATIONS, 1999, 167 (1-6) :77-82
[5]  
Boisde G, 1996, CHEM BIOCH SENSING O
[6]  
Chang R.K., 1996, OPTICAL PROCESSES MI
[7]   Microfabricated devices in biotechnology and biochemical processing [J].
Chován, T ;
Guttman, A .
TRENDS IN BIOTECHNOLOGY, 2002, 20 (03) :116-122
[8]   Novel bioaffinity sensors for trace analysis based on luminescence excitation by planar waveguides [J].
Duveneck, GL ;
Pawlak, M ;
Neuschafer, D ;
Bar, E ;
Budach, W ;
Pieles, U .
SENSORS AND ACTUATORS B-CHEMICAL, 1997, 38 (1-3) :88-95
[9]  
DUVENECK GL, 2002, ANAL CHIM ACTA, P1
[10]   Array Biosensor: Optical and Fluidics Systems [J].
Feldstein, Mark J. ;
Golden, Joel P. ;
Rowe, Chris A. ;
MacCraith, Brian D. ;
Ligler, Frances S. .
BIOMEDICAL MICRODEVICES, 1999, 1 (02) :139-153