Evaluation of flow in the left anterior descending coronary artery but not in the left internal mammary artery graft predicts significant stenosis of the arterial conduit

被引:21
作者
Pizzuto, F
Voci, P
Mariano, E
Puddu, PE
Aprile, A
Romeo, F
机构
[1] Univ Roma La Sapienza, Dept Cardiol, Rome, Italy
[2] Univ Roma La Sapienza, Dept Cardiothorac & Vasc Sci A Reale, Rome, Italy
[3] Univ Roma Tor Vergata, Dept Cardiol, Rome, Italy
关键词
D O I
10.1016/j.jacc.2004.09.072
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The purpose of this study was to evaluate which Doppler-derived flow index best predicts new distal left anterior descending coronary artery (LAD) stenosis in patients with left internal mammary artery (LIMA) graft. BACKGROUND The LIMA flow measurement has been proposed to assess graft function, but it may be misleading in case of new distal LAD stenosis and/or competitive flow from native LAD. Distal LAD coronary flow reserve (CFR: hyperemic/baseline peak flow velocity ratio) may be more appropriate. METHODS The LIMA and distal LAD flow was measured by transthoracic Doppler echocardiography in 96 patients undergoing diagnostic/therapeutic coronary angiography, 7 +/- 4 years after cardiac bypass surgery. The LIMA flow indexes (systolic-to-diastotic peak velocity ratio [SDPVr] > 1, diastolic time velocity integral fraction [DTVIf] <0.5, and CFR <2) and LAD CFR <2 were used to predict greater than or equal to70% new LAD stenosis. RESULTS The LAD CFR <2 predicted new LAD stenosis, found in 21 of 77 patients without competitive flow from native LAD, with significantly higher diagnostic accuracy (98%) than LIMA flow indexes (SDPVr >1 = 61%, DTVIf <0.5 = 69%, and CFR <2 = 72%). The LIMA flow indexes were abnormal in 17 of 19 patients with competitive graft flow, but only 5 had graft restriction, and none had significant LAD stenosis. In a multivariate model of new distal. LAD stenosis prediction, competitive flow from native LAD reduced the predictive role of LIMA but not of LAD CFR. CONCLUSIONS In patients without competitive flow from native LAD, LAD CFR is more accurate for the detection of LAD stenosis than LIMA CFR. In patients with competitive graft flow, abnormal LIMA flow patterns and blunted LIMA CFR do not reflect downstream LAD flow as LAD CFR does. (C) 2005 by the American College of Cardiology Foundation.
引用
收藏
页码:424 / 432
页数:9
相关论文
共 26 条
[1]   Flow dynamics of angiographically no-flow patent internal mammary artery grafts [J].
Akasaka, T ;
Yoshida, K ;
Hozumi, T ;
Takagi, T ;
Kaji, S ;
Kawamoto, T ;
Morioka, S ;
Nasu, M ;
Yoshikawa, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (05) :1049-1056
[2]   Transthoracic Doppler echocardiographic comparison of left internal mammary grafts to left anterior descending coronary artery with ungrafted right internal mammary arteries in patients with and without myocardial ischemia by dobutamine stress echocardiography [J].
Arruda, AM ;
Pellikka, PA ;
Mahoney, DW ;
Joseph, A ;
Mathias, W ;
Seward, JB .
AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (09) :919-922
[3]  
BARNER HB, 1974, ARCH SURG-CHICAGO, V109, P627
[4]   New noninvasive method for coronary flow reserve assessment - Contrast-enhanced transthoracic second harmonic echo Doppler [J].
Caiati, C ;
Montaldo, C ;
Zedda, N ;
Bina, A ;
Iliceto, S .
CIRCULATION, 1999, 99 (06) :771-778
[5]  
Calafiore AM, 1998, ANN THORAC SURG, V66, P1236, DOI 10.1016/S0003-4975(98)00520-7
[6]   NONINVASIVE ASSESSMENT OF LEFT INTERNAL MAMMARY ARTERY GRAFT PATENCY USING TRANSTHORACIC ECHOCARDIOGRAPHY [J].
CROWLEY, JJ ;
SHAPIRO, LM .
CIRCULATION, 1995, 92 (09) :25-30
[7]   EARLY AND LATE RESULTS OF CORONARY REVASCULARIZATION WITH SAPHENOUS-VEIN AND INTERNAL MAMMARY ARTERY GRAFTS [J].
GEHA, AS ;
BAUE, AE .
AMERICAN JOURNAL OF SURGERY, 1979, 137 (04) :456-463
[8]   CORONARY FLOW RESERVE AS A PHYSIOLOGIC MEASURE OF STENOSIS SEVERITY [J].
GOULD, KL ;
KIRKEEIDE, RL ;
BUCHI, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (02) :459-474
[9]  
Heller LI, 1997, CIRCULATION, V96, P484
[10]   Noninvasive assessment of significant left anterior descending coronary artery stenosis by coronary flow velocity reserve with transthoracic color Doppler echocardiography [J].
Hozumi, T ;
Yoshida, K ;
Ogata, Y ;
Akasaka, T ;
Asami, Y ;
Takagi, T ;
Morioka, S .
CIRCULATION, 1998, 97 (16) :1557-1562