Use of a three-factor interpretive optimisation strategy in the development of an isocratic chromatographic procedure for the screening of diuretics in urine samples using micellar mobile phases

被引:34
作者
Carda-Broch, S
Torres-Lapasió, JR
Esteve-Romero, JS
García-Alvarez-Coque, MC
机构
[1] Univ Valencia, Fac Quim, Dept Quim Analit, E-46100 Burjassot, Valencia, Spain
[2] Univ Jaume 1, ESTCE, Area Quim Analit, Castellon de La Plana 12080, Spain
关键词
optimization; mobile phase composition; micellar liquid chromatography; diuretics;
D O I
10.1016/S0021-9673(00)00768-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Screening of diuretics in urine is feasible through direct injection of the samples into the chromatographic system and isocratic reversed-phase liquid chromatography (RPLC) with micellar-organic mobile phases of sodium dodecyl sulfate (SDS) and I-propanol. The surfactant coverage of the chromatographic column makes the addition of organic competing amines less necessary than in conventional aqueous-organic RPLC to achieve well-shaped peaks. Also, the range of elution strengths of micellar mobile phases required to elute mixtures of hydrophobic and hydrophilic diuretics is smaller. This allows the isocratic separation of the diuretics within adequate analysis times. An interpretive methodology is applied to optimise the resolution of a mixture of 15 diuretics of diverse polarity and acid-base behaviour (althiazide, amiloride, bendroflumethiazide, benzthiazide, bumetanide, canrenoic acid, chlorthalidone, ethacrynic acid, furosemide, piretanide, probenecid, torasemide, triamterene, trichloromethiazide and xipamide), using pH and concentrations of surfactant and organic modifier in the mobile phase as separation factors. Twelve diuretics were resolved in 25 min using 0.055 M SDS-6.0% I-propanol at pH 3.0. The mixture of 15 diuretics was also resolved with two mobile phases showing complementary behaviour: 0.05 M SDS-5.6% l-propanol at pH 5.4 and 0.11 M SDS-5.4% l-propanol at pH 4.2, The results were applied to the analysis of urine samples with limits of detection similar to those usually reported for aqueous-organic RPLC, taking into account that the samples were injected without any previous treatment to separate or preconcentrate the analytes. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:321 / 337
页数:17
相关论文
共 36 条
[1]  
Alvarez-Coque MCG, 1999, J CHROMATOGR B, V736, P1
[2]  
[Anonymous], 1990, COMPREHENSIVE MED CH
[3]  
BARROSO MB, 1994, ANALYST, V119, P2359
[4]   Modelling retention in liquid chromatography as a function of solvent composition and pH of the mobile phase [J].
Bergés, R ;
Sanz-Nebot, V ;
Barbosa, J .
JOURNAL OF CHROMATOGRAPHY A, 2000, 869 (1-2) :27-39
[5]   Causes and remediation of reduced efficiency in micellar liquid chromatography [J].
Berthod, A .
JOURNAL OF CHROMATOGRAPHY A, 1997, 780 (1-2) :191-206
[6]   CHROMATOGRAPHIC MONITORING OF DIURETICS IN URINE SAMPLES USING A SODIUM DODECYL-SULFATE PROPANOL MICELLAR ELUENT [J].
BONETDOMINGO, E ;
TORRESLAPASIO, JR ;
MEDINAHERNANDEZ, MJ ;
GARCIAALVAREZCOQUE, MC .
ANALYTICA CHIMICA ACTA, 1994, 287 (03) :201-210
[7]   Chromatographic determination of diuretics in urine samples using hybrid micellar mobile phases with fluorimetric detection [J].
Carda-Broch, S ;
Esteve-Romero, JS ;
García-Alvarez-Coque, MC .
ANALYTICA CHIMICA ACTA, 1998, 375 (1-2) :143-154
[8]   COMPREHENSIVE SCREENING-PROCEDURE FOR DIURETICS IN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
COOPER, SF ;
MASSE, R ;
DUGAL, R .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 489 (01) :65-88
[9]   INFLUENCE OF THE CHAIN-LENGTH OF CHEMICALLY BONDED PHASES ON THE BEHAVIOR OF SEVERAL THIAZIDE, POTASSIUM-SPARING AND LOOP DIURETICS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
DECROO, F ;
VANDENBOSSCHE, W ;
DEMOERLOOSE, P .
JOURNAL OF CHROMATOGRAPHY, 1985, 349 (02) :301-304
[10]  
Dirks J.H., 1986, DIURETICS PHYSL PHAR