Optimization of 3D conformal electron beam therapy in inhomogeneous media by concomitant fluence and energy modulation

被引:37
作者
Asell, M
Hyodynmaa, S
Gustafsson, A
Brahme, A
机构
[1] STOCKHOLM UNIV,S-17176 STOCKHOLM,SWEDEN
[2] TAMPERE UNIV HOSP,DEPT RADIAT THERAPY,FIN-33521 TAMPERE,FINLAND
关键词
D O I
10.1088/0031-9155/42/11/006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The possibilities of using simultaneous fluence and energy modulation techniques in electron beam therapy to shape the dose distribution and almost eliminate the influences of tissue inhomogeneities have been investigated. By using a radiobiologically based optimization algorithm the radiobiological properties of the tissues can be taken into account when trying to End the best possible dose delivery. First water phantoms with differently shaped surfaces were used to study the effect of surface irregularities. We also studied water phantoms with internal inhomogeneities consisting of air or cortical bone. It was possible to improve substantially the dose distribution by fluence modulation in these cases. In addition to the fluence modulation the most suitable single electron energy in each case was also determined. Finally, the simultaneous use of several preselected electron beam energies was also tested, each with an individually optimized fluence profile. One to six electron energies were used, resulting in a slow improvement in complication-free cure with increasing number of beam energies. To apply these techniques to a more clinically relevant situation a post-operative breast cancer patient was studied. For simplicity this patient was treated with only one anterior beam portal to clearly illustrate the effect of inhomogeneities like bone and lung on the dose distribution. It is shown that by using fluence modulation the influence of dose inhomogeneities can be significantly reduced. When two or more electron beam energies with individually optimized fluence profiles are used the dose conformality to the internal target volume is further increased, particularly for targets with complex shapes.
引用
收藏
页码:2083 / 2100
页数:18
相关论文
共 45 条
[1]  
A'gren-Cronqvist A. K., 1995, THESIS STOCKHOLM U
[2]  
ABOUMANDOUR M, 1978, STRAHLENTHERAPIE, V154, P546
[3]  
Agren Cronqvist A K, 1995, Acta Oncol, V34, P851
[4]  
AGRENCRONQVIST AK, 1996, MODELLING CLIN RADIO
[5]   HIGH-ENERGY ELECTRON DOSE PERTURBATIONS IN REGIONS OF TISSUE HETEROGENEITY .2. PHYSICAL MODELS OF TISSUE HETEROGENEITIES [J].
ALMOND, PR ;
WRIGHT, AE ;
BOONE, MLM .
RADIOLOGY, 1967, 88 (06) :1146-&
[6]   MEAN ENERGY IN ELECTRON-BEAMS [J].
ANDREO, P ;
BRAHME, A .
MEDICAL PHYSICS, 1981, 8 (05) :682-687
[7]  
[Anonymous], 1984, 35 ICRU
[8]   CURRENT DEVELOPMENTS IN PROTON THERAPY - A REVIEW [J].
BONNETT, DE .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (10) :1371-1392
[9]   DESIGN PRINCIPLES AND CLINICAL POSSIBILITIES WITH A NEW GENERATION OF RADIATION-THERAPY EQUIPMENT - A REVIEW [J].
BRAHME, A .
ACTA ONCOLOGICA, 1987, 26 (06) :403-412
[10]   DOSIMETRIC PRECISION REQUIREMENTS IN RADIATION-THERAPY [J].
BRAHME, A .
ACTA RADIOLOGICA ONCOLOGY, 1984, 23 (05) :379-391