Use of a human visual system model to predict observer performance with CRT vs LCD display of images

被引:41
作者
Krupinski, EA
Johnson, J
Roehrig, H
Nafziger, J
Fan, JH
Lubin, J
机构
[1] Univ Arizona, Dept Radiol, Tucson, AZ USA
[2] Siemens Corp Res, Princeton, NJ USA
[3] Sarnoff Corp, Princeton, NJ USA
关键词
vision model; observer performance; digital display;
D O I
10.1007/s10278-004-1016-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This Project evaluated a human visual system model (JNDmetrix) based on just noticeable difference (JND) and frequency-channel vision-modeling principles to assess whether a Cathode ray tube (CRT) or a liquid crystal display (LCD) monochrome display monitor would yield better observer performance in radiographic interpretation. Key physical characteristics, such as veiling glare and modulation transfer function (MTF) of the CRT and LCD were measured. Regions of interest from mammographic images with masses of different contrast levels were shown once on each display to six radiologists using a counterbalanced presentation order. The images were analyzed using the JNDmetrix model. Performance as measured by receiver operating characteristic (ROC) analysis was significantly better overall on the LCD display (P = 0.0120). The JNDmetrix model predicted the result (P = 0.0046) and correlation between human and computer observers was high (r(2) (quadratic) = 0.997). The results suggest that observer performance with LCD displays is superior to CRT viewing, at least for on-axis viewing.
引用
收藏
页码:258 / 263
页数:6
相关论文
共 19 条
[1]   Method for measuring veiling glare in high-performance display devices [J].
Badano, A ;
Flynn, MJ .
APPLIED OPTICS, 2000, 39 (13) :2059-2066
[2]   Effect of viewing angle on visual detection in liquid crystal displays [J].
Badano, A ;
Gallas, BD ;
Myers, KJ ;
Burgess, AE .
MEDICAL IMAGING 2003: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2003, 5029 :474-483
[3]   Angular dependence of the luminance and contrast in medical monochrome liquid crystal displays [J].
Badano, A ;
Flynn, MJ ;
Martin, S ;
Kanicki, J .
MEDICAL PHYSICS, 2003, 30 (10) :2602-2613
[4]  
Badano A, 2003, ADV DIGITAL RADIOGRA, P91
[5]  
Bennett W F, 2002, J Digit Imaging, V15 Suppl 1, P171, DOI 10.1007/s10278-002-5070-5
[6]   Characterization of high-resolution liquid-crystal displays for medical images [J].
Blume, H ;
Steven, PM ;
Cobb, M ;
Ho, AM ;
Stevens, F ;
Muller, S ;
Roehrig, H ;
Fan, JH .
MEDICAL IMAGING 2002: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2002, 4681 :271-292
[7]   RECEIVER OPERATING CHARACTERISTIC RATING ANALYSIS - GENERALIZATION TO THE POPULATION OF READERS AND PATIENTS WITH THE JACKKNIFE METHOD [J].
DORFMAN, DD ;
BERBAUM, KS ;
METZ, CE .
INVESTIGATIVE RADIOLOGY, 1992, 27 (09) :723-731
[8]  
HORII SC, 2002, PACS GUIDE DIGITAL R, P191
[9]   Enterprise PACS and image distribution [J].
Huang, HK .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2003, 27 (2-3) :241-253
[10]   Some historical remarks on picture archiving and communication systems [J].
Huang, HK .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2003, 27 (2-3) :93-99