Blunt traumatic aortic transection: The endovascular experience

被引:72
作者
Orford, VP
Atkinson, NR
Thomson, K
Milne, PY
Campbell, WA
Roberts, A
Goldblatt, J
Tatoulis, J
机构
[1] Royal Melbourne Hosp, Cardiothorac Surg Unit, Dept Radiol, Parkville, Vic 3050, Australia
[2] Royal Melbourne Hosp, Vasc Surg Unit, Dept Radiol, Parkville, Vic 3050, Australia
[3] Austin & Repatriat Med Ctr, Vasc Surg Unit, Melbourne, Vic, Australia
[4] Alfred Hosp, Vasc Surg Unit, Melbourne, Vic, Australia
关键词
D O I
10.1016/S0003-4975(02)04331-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Thoracic aortic transection resulting from blunt trauma is usually fatal. It is almost always associated with multiple, complex, nonaortic injuries that could be adversely affected by standard surgical repair of the aorta. Endovascular stenting techniques offer these patients a less physiologically disruptive treatment option. We studied the feasibility and safety of endovascular stent graft placement for treatment of acute traumatic aortic transection. Methods. Between 1994 and 2001, 9 patients were treated emergently for aortic transections with stent graft placement. The first patient had a custom-made prototype, and the other 8 patients had the Cook-Zenith thoracic stent graft implanted. All were polyester covered Z-stent construction and deployed through a femoral 20- to 24-F delivery sheath. Results. Stent graft placement successfully sealed the aorta in all patients. One patient died as a result of a cerebrovascular accident. One patient required a brachial thrombectomy to relieve arm ischemia. The remaining eight patients were alive and without complications during the follow-up period (mean 21 months). Conclusions. Endovascular repair for acute aortic transection is a safe, effective, and timely treatment option. It may be the treatment of choice in patients with extensive associated injuries. (C) 2003 by The Society of Thoracic Surgeons.
引用
收藏
页码:106 / 111
页数:6
相关论文
共 13 条
[1]  
COWLEY RA, 1990, J THORAC CARDIOV SUR, V100, P652
[2]   TRANSLUMINAL PLACEMENT OF ENDOVASCULAR STENT-GRAFTS FOR THE TREATMENT OF DESCENDING THORACIC AORTIC-ANEURYSMS [J].
DAKE, MD ;
MILLER, DC ;
SEMBA, CP ;
MITCHELL, RS ;
WALKER, PJ ;
LIDDELL, RP .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (26) :1729-1734
[3]   Prospective study of blunt aortic injury: Multicenter trial of the American Association for the Surgery of Trauma [J].
Fabian, TC ;
Richardson, JD ;
Croce, MA ;
Smith, JS ;
Rodman, G ;
Kearney, PA ;
Flynn, W ;
Ney, AL ;
Cone, JB ;
Luchette, FA ;
Wisner, DH ;
Scholten, DJ ;
Beaver, BL ;
Conn, AK ;
Coscia, R ;
Hoyt, DB ;
Morris, JA ;
Harviel, JD ;
Peitzman, AB ;
Bynoe, RP ;
Diamond, DL ;
Wall, M ;
Gates, JD ;
Asensio, JA ;
McCarthy, MC ;
Girotti, MJ ;
VanWijngaarden, M ;
Cogbill, TH ;
Levison, MA ;
Aprahamian, C ;
Sutton, JE ;
Allen, CF ;
Hirsch, EF ;
Nagy, K ;
Bachulis, BL ;
Bales, CR ;
Shapiro, MJ ;
Metzler, MH ;
Conti, VR ;
Baker, CC ;
Bannon, MP ;
Ochsner, MG ;
Thomason, MH ;
Hiatt, JR ;
OMalley, K ;
Obeid, FN ;
Gray, P ;
Bankey, PE ;
Knudson, MM ;
Dyess, DL .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1997, 42 (03) :374-380
[4]   Traumatic thoracic aortic aneurysm: Treatment with endovascular stent-grafts [J].
Kato, N ;
Dake, MD ;
Miller, DC ;
Semba, CP ;
Mitchell, RS ;
Razavi, MK ;
Kee, ST .
RADIOLOGY, 1997, 205 (03) :657-662
[5]  
MARIN ML, 1995, ANN SURG, V222, P449
[6]  
Mitchell R S, 1997, Semin Vasc Surg, V10, P257
[7]   NONPENETRATING TRAUMATIC INJURY OF THE AORTA [J].
PARMLEY, LF ;
MATTINGLY, TW ;
MANION, WC ;
JAHNKE, EJ .
CIRCULATION, 1958, 17 (06) :1086-1101
[8]  
Parodi J C, 1991, Ann Vasc Surg, V5, P491, DOI 10.1007/BF02015271
[9]   Delayed treatment of traumatic rupture of the thoracic aorta with endoluminal covered stent [J].
Rousseau, H ;
Soula, P ;
Perreault, P ;
Bui, B ;
d'Othée, BJ ;
Massabuau, P ;
Meites, G ;
Concina, P ;
Mazerolles, M ;
Joffre, F ;
Otal, P .
CIRCULATION, 1999, 99 (04) :498-504
[10]   TRAUMATIC RUPTURE OF THE AORTA - STILL A LETHAL INJURY [J].
SMITH, RS ;
CHANG, FC .
AMERICAN JOURNAL OF SURGERY, 1986, 152 (06) :660-663