Magnetic resonance imaging to assess acute changes in atrial and ventricular parameters after transcatheter closure of atrial septal defects

被引:23
作者
Burgstahler, Christof
Woehrle, Jochen
Kochs, Matthias
Nusser, Thorsten
Loeffler, Christine
Kunze, Markus
Hoeher, Martin
Gawaz, Meinrad P.
Hombach, Vinzenz
Merkle, Nico
机构
[1] Univ Ulm, Dept Internal Med 2, Div Cardiol, D-89081 Ulm, Germany
[2] Univ Tubingen, Dept Internal Med 3, Div Cardiol, Tubingen, Germany
[3] Bayreuth Hosp, Div Cardiol, Dept Internal Med 5, Bayreuth, Germany
关键词
magnetic resonance imaging; atrial septal defect; occluder; shunt; device;
D O I
10.1002/jmri.20911
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate acute changes in atrial and ventricular parameters by the use of cardiac magnetic resonance imaging (MRI) in patients with percutaneous transcatheter atrial septal defects (ASD) closure. Materials and Methods: The study included 14 patients (six males and eight females, 45 +/- 18 years) with congenital ASD. Cardiac MRI (1.5T Philips Intera CV) was per-formed before and within 24 hours after transcatheter ASD closure. Right atrial (RA) and left atria] (LA) dimensions, as well as right (RV) and left (LM ventricular end-diastolic (ED) volumes were determined. Atrial size was assessed by planimetry of the maximum RA and LA areas in a standard four-chamber view, and ventricular volumes were calculated according to a modified Simpson's rule in short-axis views. Results: The mean RA decreased significantly from 27.6 +/- 6.4 cm(2) before closure to 24.4 +/- 5.6 cm(2) after the procedure (P = 0.0018), whereas the LA area did not change (24.1 +/- 4.7 cm(2) vs. 23.8 +/- 5.2 cm(2), p = 0.76). The RV volumes, volume index, and ejection fraction (EF) decreased significantly from 229 +/- 64 mL to 181 +/- 43 mL (P < 0.001, average reduction = 19% +/- 15%), from 126.0 +/- 37.2 mL/m(2) to 96.6 +/- 28.6 mL/m(2) (P < 0.0001) and from 64 +/- 5% to 58% +/- 7% (P = 0.01), respectively. The LV volumes and volume index remained unchanged (114 +/- 25 mL vs. 118 +/- 22 mL, P 0.18, 63.5 +/- 13.5 mL/m(2) vs. 63.0 +/- 17.4 mL/m(2), p 0.83). Left-right shunting decreased from 40% +/- 15% to 9% +/- 15% (P < 0.001). Conclusion: Cardiac MRI can reveal detailed information on acute changes in shunt fraction and ventricular dimensions after ASD closure. ASD closure by percutaneous transcatheter device implantation results within 24 hours in a significant reduction of shunt fraction, RA and RV sizes, and RV function, whereas LA and LV dimensions remain unchanged.
引用
收藏
页码:1136 / 1140
页数:5
相关论文
共 22 条
[1]   Atrial septal defects in pediatric patients:: Noninvasive sizing with cardiovascular MR imaging [J].
Beerbaum, P ;
Körperich, H ;
Esdorn, H ;
Blanz, U ;
Barth, P ;
Hartmann, J ;
Gieseke, J ;
Meyer, H .
RADIOLOGY, 2003, 228 (02) :361-369
[2]   Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance [J].
Bellenger, NG ;
Davies, LC ;
Francis, JM ;
Coats, AJS ;
Pennell, DJ .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2000, 2 (04) :271-278
[3]   Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance - Are they interchangeable? [J].
Bellenger, NG ;
Burgess, MI ;
Ray, SG ;
Lahiri, A ;
Coats, AJS ;
Cleland, JGF ;
Pennell, DJ .
EUROPEAN HEART JOURNAL, 2000, 21 (16) :1387-1396
[4]   Practical value of cardiac magnetic resonance imaging for clinical quantification of aortic valve stenosis comparison with echocardiography [J].
Caruthers, SD ;
Lin, SJ ;
Brown, P ;
Watkins, MP ;
Williams, TA ;
Lehr, KA ;
Wickline, SA .
CIRCULATION, 2003, 108 (18) :2236-2243
[5]   RIGHT-VENTRICULAR VOLUME ESTIMATION WITH AN ELLIPSOIDAL SHELL-MODEL AND 2-PLANE MAGNETIC-RESONANCE-IMAGING [J].
DENSLOW, S ;
WILES, HB ;
MCKELLAR, LF ;
WRIGHT, NA ;
GILLETTE, PC .
AMERICAN HEART JOURNAL, 1995, 129 (04) :782-790
[6]   Right ventricular volume estimation using an ellipsoidal shell model and single-plane magnetic resonance imaging [J].
Denslow, S ;
Wiles, HB ;
McKellar, LF ;
Wright, NA ;
Gillette, PC .
INVESTIGATIVE RADIOLOGY, 1996, 31 (01) :17-25
[7]   Transcatheter closure of atrial septal defect preserves right ventricular function [J].
Dhillon, R ;
Josen, M ;
Henein, M ;
Redington, A .
HEART, 2002, 87 (05) :461-465
[8]  
Durongpisitkul Kritvikrom, 2002, Journal of the Medical Association of Thailand, V85, pS658
[9]   INTERSTUDY VARIABILITY IN LEFT-VENTRICULAR MASS MEASUREMENT - COMPARISON BETWEEN M-MODE ECHOGRAPHY AND MRI [J].
GERMAIN, P ;
ROUL, G ;
KASTLER, B ;
MOSSARD, JM ;
BAREISS, P ;
SACREZ, A .
EUROPEAN HEART JOURNAL, 1992, 13 (08) :1011-1019
[10]   Surgical closure of atrial septal defects in adults: effect of age at operation on outcome [J].
Ghosh, S ;
Chatterjee, S ;
Black, E ;
Firmin, RK .
HEART, 2002, 88 (05) :485-487