Efficacy of thermal treatment and copper-silver ionization for controlling Legionella pneumophila in high-volume hot water plumbing systems in hospitals

被引:55
作者
Miuetzner, S [1 ]
Schwille, RC [1 ]
Farley, A [1 ]
Wald, ER [1 ]
Ge, JH [1 ]
States, SJ [1 ]
Libert, T [1 ]
Wadowsky, RM [1 ]
机构
[1] Childrens Hosp Pittsburgh, Dept Pediat, Pittsburgh, PA 15213 USA
关键词
D O I
10.1016/S0196-6553(97)90066-3
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Thermal treatment and copper-silver ionization are often used for controlling Legionella pneumophila in high-volume hospital plumbing systems, although the comparative efficacies of these measures in high-volume systems are unknown. Methods: Thermal treatment of a hot water circuit was accomplished by flushing hot water (>60 degrees C) through distal fixtures for 10 minutes. Copper-silver ionization was conducted in three circuits by installing units into return lines immediately upstream from hot water tanks. Recovery rates of L. pneumophila were monitored by culturing swab samples from faucets, Concentrations of copper and silver in water samples were determined by atomic absorption spectrophotometry. Results: Four heat-flush treatments failed to provide long-term control oft. pneumophila. In contrast, ionization treatment reduced the rate of recovery of L. pneumophila from 108 faucets from 72% to 2% within 1 month and maintained effective control for at least 22 months. Only three samples (1.9%) of hot water from faucets exceeded Environmental Protection Agency standards for silver, and none exceeded the standards for copper. Of 24 samples obtained from hot water tanks, 42% and 50% exceeded the silver and copper standards, respectively Conclusions: Copper-silver ionization effectively controls L. pneumophila in high-volume plumbing systems and is superior to thermal treatment; however, high concentrations of copper and silver can accumulate at the bottom of hot water tanks.
引用
收藏
页码:452 / 457
页数:6
相关论文
共 22 条
[1]  
*ALL COUNT HLTH DE, 1995, APPR PREV CONTR LEG
[2]   AEROSOLS CONTAINING LEGIONELLA-PNEUMOPHILA GENERATED BY SHOWER HEADS AND HOT-WATER FAUCETS [J].
BOLLIN, GE ;
PLOUFFE, JF ;
PARA, MF ;
HACKMAN, B .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1985, 50 (05) :1128-1131
[3]   ISOLATION OF LEGIONELLA SPP FROM ENVIRONMENTAL WATER SAMPLES BY LOW-PH TREATMENT AND USE OF A SELECTIVE MEDIUM [J].
BOPP, CA ;
SUMNER, JW ;
MORRIS, GK ;
WELLS, JG .
JOURNAL OF CLINICAL MICROBIOLOGY, 1981, 13 (04) :714-719
[4]   ASSOCIATION OF SHOWER USE WITH LEGIONNAIRES-DISEASE - POSSIBLE ROLE OF AMEBAS [J].
BREIMAN, RF ;
FIELDS, BS ;
SANDEN, GN ;
VOLMER, L ;
MEIER, A ;
SPIKA, JS .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1990, 263 (21) :2924-2926
[5]  
BREIMAN RF, 1991, 91 GEN M AM SOC MICR
[6]  
CHERRY WB, 1978, J CLIN MICROBIOL, V8, P329
[7]   OUTBREAK OF LEGIONNAIRES-DISEASE AT UNIVERSITY-HOSPITAL, NOTTINGHAM - EPIDEMIOLOGY, MICROBIOLOGY AND CONTROL [J].
COLVILLE, A ;
CROWLEY, J ;
DEARDEN, D ;
SLACK, RCB ;
LEE, JV .
EPIDEMIOLOGY AND INFECTION, 1993, 110 (01) :105-116
[8]  
*COMM MED BIOL EFF, 1977, COPPER
[9]   Field inversion gel electrophoretic analysis of Legionella pneumophila strains associated with nosocomial legionellosis in children [J].
Green, M ;
Wald, ER ;
Dashefsky, B ;
Barbadora, K ;
Wadowsky, RM .
JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (01) :175-176
[10]  
GUSTAFSON TL, 1986, EPISTAT SOFTWARE PAC