Quantification of right and left ventricular function by cardiovascular magnetic resonance

被引:55
作者
Bellenger, NG
Grothues, F
Smith, GC
Pennell, DJ
机构
[1] Royal Brompton Hosp, Cardiovasc MR Unit, London SW3 6NP, England
[2] Univ Magdeburg, Klin Kardiol Angiol & Pneumol, D-39106 Magdeburg, Germany
关键词
cardiac imaging; MRI; heart; ventricular function;
D O I
10.1007/s000590050031
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cardiac dysfunction is a major cause of cardiovascular morbidity and mortality. Accurate and reproducible assessment of cardiac function is essential for the diagnosis, the assessment of prognosis and evaluation of a patient's response to therapy. Cardiovascular Magnetic Resonance (CMR) provides a measure of global and regional function that is not only accurate and reproducible but is noninvasive, free of ionising radiation, and independent of the geometric assumptions and acoustic windows that limit echocardiography. With the advent of faster scanners, automated analysis, increasing availability and reducing costs, CMR is fast becoming a clinically tenable reference standard for the measurement of cardiac function.
引用
收藏
页码:392 / 399
页数:8
相关论文
共 41 条
[1]   MEASUREMENT OF LEFT-VENTRICULAR MASS IN HYPERTROPHIC CARDIOMYOPATHY USING MRI - COMPARISON WITH ECHOCARDIOGRAPHY [J].
ALLISON, JD ;
FLICKINGER, FW ;
WRIGHT, JC ;
FALLS, DG ;
PRISANT, LM ;
VONDOHLEN, TW ;
FRANK, MJ .
MAGNETIC RESONANCE IMAGING, 1993, 11 (03) :329-334
[2]  
AXEL L, 1989, RADIOLOGY, V178, P357
[3]   COMPARISON OF LOW-DOSE DOBUTAMINE GRADIENT-ECHO MAGNETIC-RESONANCE-IMAGING AND POSITRON EMISSION TOMOGRAPHY WITH [F-18] FLUORODEOXYGLUCOSE IN PATIENTS WITH CHRONIC CORONARY-ARTERY DISEASE - A FUNCTIONAL AND MORPHOLOGICAL APPROACH TO THE DETECTION OF RESIDUAL MYOCARDIAL VIABILITY [J].
BAER, FM ;
VOTH, E ;
SCHNEIDER, CA ;
THEISSEN, P ;
SCHICHA, H ;
SECHTEM, U .
CIRCULATION, 1995, 91 (04) :1006-1015
[4]  
Bellenger NG, 1999, CLINICAL GATED CARDIAC SPECT, P349
[5]  
Bellenger NG, 1999, J CARDIOVASC MR, V1, P323
[6]  
BELLENGER NG, 1999, J CARDIOV MAGN RESON, V1, P287
[7]   Global cardiac function using fast breath-hold MRI: Validation of new acquisition and analysis techniques [J].
Bloomgarden, DC ;
Fayad, ZA ;
Ferrari, VA ;
Chin, B ;
Sutton, MGSJ ;
Axel, L .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (05) :683-692
[8]  
Bogaert J G, 1995, MAGMA, V3, P5, DOI 10.1007/BF02426395
[9]   MAGNETIC-RESONANCE-IMAGING COMPARED TO ECHOCARDIOGRAPHY TO ASSESS LEFT-VENTRICULAR MASS IN THE HYPERTENSIVE PATIENT [J].
BOTTINI, PB ;
CARR, AA ;
PRISANT, LM ;
FLICKINGER, FW ;
ALLISON, JD ;
GOTTDIENER, JS .
AMERICAN JOURNAL OF HYPERTENSION, 1995, 8 (03) :221-228
[10]   NONINVASIVE EVALUATION OF GLOBAL LEFT-VENTRICULAR FUNCTION WITH USE OF CINE NUCLEAR MAGNETIC-RESONANCE [J].
BUSER, PT ;
AUFFERMANN, W ;
HOLT, WW ;
WAGNER, S ;
KIRCHER, B ;
WOLFE, C ;
HIGGINS, CB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (06) :1294-1300