Povidone iodine and skin disinfection before initiation of epidural anesthesia

被引:45
作者
Birnbach, DJ
Stein, DJ
Murray, O
Thys, DM
Sordillo, EM
机构
[1] Columbia Univ, St Lukes Roosevelt Hosp Ctr, Dept Anesthesiol, Coll Phys & Surg, New York, NY 10019 USA
[2] Columbia Univ, St Lukes Roosevelt Hosp Ctr, Dept Pathol & Lab Med, Coll Phys & Surg, New York, NY 10019 USA
关键词
bacteria; contamination; infection;
D O I
10.1097/00000542-199803000-00017
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Povidone iodine (PI) solution is used commonly for skin disinfection before epidural and spinal anesthesia. Although there have been reports indicating the presence of microbial contaminants in PI solution, none have evaluated the prevalence of PI contamination. The aims of this study were to assess the frequency of bacterial contamination of previously opened bottles of PI solution and to compare the effectiveness of new and previously opened bottles of PI solution for skin disinfection. Methods: Twenty previously opened and ten previously unopened multiple-use bottles of PI solution were evaluated for microbial contamination. In addition, final swabs and PI solution used for skin disinfection in 80 patients undergoing elective epidural analgesia were evaluated. Results: The inside of the bottle cap or the PI solution from 40% of the multiple-use PI bottles in use were contaminated. There was no growth from any previously unused PI bottles. Povidone iodine from newly opened bottles provided more effective skin decontamination than did solution from previously opened bottles. Conclusions: Multiple-use PI bottles in normal use may become contaminated by bacteria. In addition, PI solution from previously opened bottles was less effective than PI from previously unopened bottles. Based on these findings, if PI solution is chosen for skin antisepsis before initiation of epidural and spinal anesthesia, only single-use containers should be used.
引用
收藏
页码:668 / 672
页数:5
相关论文
共 15 条
[1]  
BERGA S, 1989, OBSTET GYNECOL, V74, P437
[2]   EPIDURAL ABSCESS AFTER OBSTETRIC EPIDURAL ANALGESIA [J].
BORUM, SE ;
MCLESKEY, CH ;
WILLIAMSON, JB ;
HARRIS, FS ;
KNIGHT, AB .
ANESTHESIOLOGY, 1995, 82 (06) :1523-1526
[3]   SPINAL EXTRADURAL ABSCESS - PURSUIT OF VIGILANCE [J].
BROMAGE, PR .
BRITISH JOURNAL OF ANAESTHESIA, 1993, 70 (04) :471-473
[4]   PSEUDOBACTEREMIA CAUSED BY POVIDONE-IODINE SOLUTION CONTAMINATED WITH PSEUDOMONAS-CEPACIA [J].
CRAVEN, DE ;
MOODY, B ;
CONNOLLY, MG ;
KOLLISCH, NR ;
STOTTMEIER, KD ;
MCCABE, WR .
NEW ENGLAND JOURNAL OF MEDICINE, 1981, 305 (11) :621-623
[5]   POSTPARTUM MENINGITIS [J].
DAVIS, L ;
HARGREAVES, C ;
ROBINSON, PN .
ANAESTHESIA, 1993, 48 (09) :788-789
[6]   TIME-DEPENDENT EFFICACY OF BACTERIAL FILTERS AND INFECTION RISK IN LONG-TERM EPIDURAL CATHETERIZATION [J].
DECICCO, M ;
MATOVIC, M ;
CASTELLANI, GT ;
BASAGLIA, G ;
SANTINI, G ;
DELPUP, C ;
FANTIN, D ;
TESTA, V .
ANESTHESIOLOGY, 1995, 82 (03) :765-771
[7]  
Edwards Waldo B., 1943, BULL NEW YORK ACAD MED, V19, P507
[8]   EXTRADURAL ABSCESS COMPLICATING EXTRADURAL ANESTHESIA FOR CESAREAN-SECTION [J].
KEE, WDN ;
JONES, MR ;
THOMAS, P ;
WORTH, RJ .
BRITISH JOURNAL OF ANAESTHESIA, 1992, 69 (06) :647-652
[9]  
KILPATRICK ME, 1983, ANESTH ANALG, V62, P513
[10]   BACTERIAL-MENINGITIS IN PARTURIENTS AFTER EPIDURAL-ANESTHESIA [J].
READY, LB ;
HELFER, D .
ANESTHESIOLOGY, 1989, 71 (06) :988-990