Blepharoptosis surgery complicated by late suture migration

被引:15
作者
Foster, JA [1 ]
John, KB [1 ]
机构
[1] Cleveland Clin Fdn, Cole Eye Inst, Dept Ophthalm Plast & Reconstruct Surg, Cleveland, OH 44195 USA
关键词
D O I
10.1016/S0002-9394(00)00467-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To report late suture migration as a complication of blepharoptosis surgery. METHOD: Case reports. RESULTS: After upper eyelid blepharoptosis repair, two eyes of two patients developed unusual foreign body reactions and ulceration in the conjunctiva caused by migration of nonabsorbable suture from the levator aponeurosis to the upper conjunctival fornix. The foreign body caused eyelid edema, papillary changes in the upper tarsal conjunctiva, recurrent blepharoptosis, and a foreign body sensation that started more than 3 months after the surgery and persisted until the suture was removed. The sutures, hidden in edematous conjunctiva of the superior fornix, eluded detection. CONCLUSIONS: Foreign body reaction secondary to suture migration is an uncommon complication of blepharoptosis repair. (C) 2000 by Elsevier Science Inc. All rights reserved.
引用
收藏
页码:116 / 117