Microarray of recombinant antibodies using a streptavidin sensor surface self-assembled onto a gold layer

被引:33
作者
Pavlickova, P
Knappik, A
Kambhampati, D
Ortigao, F
Hug, H
机构
[1] Univ Ulm, Ulm, Germany
[2] MorphoSys AG, Munich, Germany
[3] ThermoHybaid GmbH, Ulm, Germany
关键词
D O I
10.2144/03341rr03
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We have developed a sensitive method for the detection of recombinant antibody-antigen interactions in a microarray format. The biochip sensor platform used in this study is based on an oriented streptavidin monolayer that provides a biological interface with well-defined surface architecture that dramatically reduces nonspecific binding interactions. All the antibody or antigen probes were biotinylated and coupled onto streptavidin-coated biochip surfaces (I muL total volume). The detection limits for the immobilized probes on the microarray surface were 0.5 mug/mL (200 fmol/spot)for the peptide antigen and 0.1 mug/mL (3 fmol/spot) for the recombinant antibodies. Optimal concentrations for the detection of the Cy5-labeled protein target were in the range of 20 mug/mL. Protein microchips were used to measure antibody-antigen kinetics, to find optimal temperature conditions, and to establish the shelf life of recombinant antibodies immobilized on the streptavidin surface. For recombinant antibody fragments with a kDa of 10-100 nM, we have established an easy and direct immunoassay. In addition, we developed an indirect method for antibody detection with no need for expensive and time-consuming antibody purifications and modifications. Such a method was shown to be useful for large-scale screening of recombinant antibody fragments directly after their functional expression in bacteria. Our data demonstrate that recombinant antibody fragments are suitable components in the construction of antibody chips.
引用
收藏
页码:124 / 130
页数:7
相关论文
共 29 条
[1]   A method of reversible Biomolecular immobilization for the surface plasmon resonance quantitative analysis of interacting biological macromolecules [J].
Benítez, MJ ;
Jiménez, JS .
ANALYTICAL BIOCHEMISTRY, 2002, 302 (02) :161-168
[2]   Protein chips based on recombinant antibody fragments:: A highly sensitive approach as detected by mass spectrometry [J].
Borrebaeck, CAK ;
Ekström, S ;
Hager, ACM ;
Nilsson, J ;
Laurell, T ;
Marko-Varga, G .
BIOTECHNIQUES, 2001, 30 (05) :1126-+
[3]   Exploring the new world of the genome with DNA microarrays [J].
Brown, PO ;
Botstein, D .
NATURE GENETICS, 1999, 21 (Suppl 1) :33-37
[4]   Antibody arrays for high-throughput screening of antibody-antigen interactions [J].
de Wildt, RMT ;
Mundy, CR ;
Gorick, BD ;
Tomlinson, IM .
NATURE BIOTECHNOLOGY, 2000, 18 (09) :989-994
[5]   BINDING OF THE INTEGRIN MAC-1 (CD11B/CD18) TO THE 3RD IMMUNOGLOBULIN-LIKE DOMAIN OF ICAM-1 (CD54) AND ITS REGULATION BY GLYCOSYLATION [J].
DIAMOND, MS ;
STAUNTON, DE ;
MARLIN, SD ;
SPRINGER, TA .
CELL, 1991, 65 (06) :961-971
[6]   The FLAG™ peptide, a versatile fusion tag for the purification of recombinant proteins [J].
Einhauer, A ;
Jungbauer, A .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2001, 49 (1-3) :455-465
[7]  
Figeys D, 2002, PROTEOMICS, V2, P373, DOI 10.1002/1615-9861(200204)2:4<373::AID-PROT373>3.0.CO
[8]  
2-I
[9]  
Haab BB, 2001, GENOME BIOL, V2
[10]   Characterization of the carbohydrate binding specificity and kinetic parameters of lectins by using surface plasmon resonance [J].
Haseley, SR ;
Talaga, P ;
Kamerling, JP ;
Vliegenthart, JFG .
ANALYTICAL BIOCHEMISTRY, 1999, 274 (02) :203-210