Critical velocity and burning rate in pool fire during longitudinal ventilation

被引:89
作者
Roh, Jae Seong
Ryou, Hong Sun [1 ]
Kim, Dong Hyeon
Jung, Woo Sung
Jang, Yong Jun
机构
[1] Chung Ang Univ, Sch Mech Engn, Seoul 156756, South Korea
[2] Korea Railway Res Inst, Gyeonggi 437757, South Korea
关键词
backlayering; burning rate; critical velocity; heat release rate; tunnel fire;
D O I
10.1016/j.tust.2006.08.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Since the prediction of 'critical velocity' is important to control the smoke in tunnel fires, many researches have been carried out to predict critical velocity with various fire sizes, tunnel shape, tunnel slope, and so forth. But few researches have been conducted to estimate critical ventilation velocity for varied burning rate by longitudinal ventilation, although burning rate of fuel is influenced by ventilation conditions. Therefore, there is a need to investigate the difference of upstream smoke layer (e.g., backlayering) between naturally ventilated heat release rate and varied heat release rate by longitudinal ventilation. In this study, the 1/20 reduced-scale experiments using Froude scaling are conducted to examine the difference of backlayering between naturally ventilated heat release rate and varied heat release rate by longitudinal ventilation. And the experimental results obtained are compared with numerical ones. Three-dimensional simulations of smoke flow in the tunnel fire with the measured burning rates have been carried out using Fire Dynamics Simulator; Ver. 406 code, which is developed by National Institute of Standards and Technology. They show a good degree of agreement, even if some deviation in temperature downstream of the fire is evident. Since ventilation velocity had a greater enhancing effect on the burning rate of fuel due to oxygen supply effect, the critical ventilation velocity should be calculated on the basis of varied HRR by ventilation velocity. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:262 / 271
页数:10
相关论文
共 17 条
[1]  
Burgess D., 1961, FIR RES ABSTR REV, V3, P177
[2]   Variation of heat release rate with forced longitudinal ventilation for vehicle fires in tunnels [J].
Carvel, RO ;
Beard, AN ;
Jowitt, PW ;
Drysdale, DD .
FIRE SAFETY JOURNAL, 2001, 36 (06) :569-596
[3]  
CARVEL RO, 2001, CIVIL ENG ENV SYSTEM, V18
[4]  
Danziger NH, 1982, P 4 INT S AER VENT V, P169
[5]  
Heselden A.J.M., 1976, P 2 INT S AER VENT V
[6]  
HINKLEY PL, 1970, 80M FIR RES
[7]  
KIM SC, 2003, THESIS CHUNG ANG U S
[8]   An experimental study of the effect of the aspect ratio on the critical velocity in longitudinal ventilation tunnel fires [J].
Lee, SR ;
Ryou, HS .
JOURNAL OF FIRE SCIENCES, 2005, 23 (02) :119-138
[9]  
McCaffrey B.J., 1977, HEAT TRANSFER TURBUL, P457
[10]  
MCCGRATTAN K, 2004, USERS GUIDE NATL I S, V1019