Influence of ceramic and stainless steel brackets on the notching of archwires during clinical treatment

被引:28
作者
Articolo, LC [1 ]
Kusy, K [1 ]
Saunders, CR [1 ]
Kusy, RP [1 ]
机构
[1] Univ N Carolina, Sch Dent, Dent Res Ctr, Chapel Hill, NC 27599 USA
关键词
D O I
10.1093/ejo/22.4.409
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
The surface topography of 100 clinically used archwires of stainless steel, beta-, or nickel-titanium were investigated that had contacted either ceramic or stainless steel brackets. One group consisted of two sets: 60 wires with no treatment records accessed to bias analyses, and 40 wires for which extensive clinical records were available, half of which were used with ceramic or stainless steel brackets. A control group consisted of two sets: 30 unused wires comprised of five round and rectangular wires of each alloy, and four wires that were ligated and immediately removed from patients' mouths. After ultrasonic cleaning, each wire was inspected under an optical and/or a scanning electron microscope. Notches were categorized with regard to frequency, patterns, and severity, and mapped as a function of wire aspect (lingual, facial, and occlusal/gingival) and anatomical regions (molar, premolar, canine, and incisor). From these data the average severity of notch patterns and a notching index were derived. Although no recognizable defect patterns were observed in the control group, seven basic patterns were recognized for each wire cross-sectional shape in the clinically used wires. These wires appeared most damaged on their lingual aspect and least damaged on their facial aspect. With regard to anatomical regions, notching was prevalent in the anterior regions and sparse in the molar regions. The notch activity and the severity were nearly three times greater from ceramic brackets than from stainless steel brackets. Over one-third of all notches documented in ceramic bracket cases had severity numbers of 3 and penetrated at least one-quarter of each wire's dimension, However, over two-thirds of all notches documented in stainless steel bracket cases had severity numbers of 1. From these tabulations a theory of notch formation was proposed in which vertical movement from tooth or wire during mastication caused fretting wear, and horizontal movement during orthodontic procedures such as space closure, tipping, or bodily movement caused sliding wear.
引用
收藏
页码:409 / 425
页数:17
相关论文
共 19 条
[1]
ABSON DJ, 1973, SCI HARDNESS TESTING
[2]
[Anonymous], 1973, SCI HARDNESS TESTING
[3]
Influence of angulation on the resistance to sliding fixed appliances [J].
Articolo, LC ;
Kusy, RP .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1999, 115 (01) :39-51
[4]
Blau P.J., 1989, FRICTION WEAR TRANSI
[5]
CZICHOS H, 1986, TRIBOLOGY SYSTEMS AP
[6]
HANSEN JD, 1998, ORTHODONTIC REV, V11, P27
[7]
Jastrzebski Z.D., 1976, Nature and Properties of Engineering Materials
[8]
JOST-BRINKMANN P, 1991, Fortschritte der Kieferorthopaedie, V52, P102, DOI 10.1007/BF02164714
[9]
ZIRCONIA BRACKETS - AN EVALUATION OF MORPHOLOGY AND COEFFICIENTS OF FRICTION [J].
KEITH, O ;
KUSY, RP ;
WHITLEY, JQ .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1994, 106 (06) :605-614
[10]
Kusy R P, 1997, Semin Orthod, V3, P166, DOI 10.1016/S1073-8746(97)80067-9