Tibial shaft axis does not always serve as a correct coronal landmark in total knee arthroplasty for varus knees

被引:40
作者
Matsuda, S [1 ]
Mizu-uchi, H [1 ]
Miura, H [1 ]
Nagamine, R [1 ]
Urabe, K [1 ]
Iwamoto, Y [1 ]
机构
[1] Kyushu Univ, Grad Sch Med Sci, Dept Orthopaed Surg, Higashi Ku, Fukuoka 8128582, Japan
关键词
total knee arthroplasty (TKA); varus knees; osteoarthritis; alignment; preoperative planning;
D O I
10.1054/arth.2003.50002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Predicted postoperative knee alignment was calculated when total knee arthroplasty was performed after 1 of 3 different methods of tibia preparation in 30 osteoarthritic knees with yarns deformity. In Method 1, the tibia was cut perpendicular to the tibial shaft. In Method 2, the tibia was cut perpendicular to a line connecting the center of the tibial plateau and the center of the talar dome. in method 3, tibial resection was determined with an original template so that tibial resection would be perpendicular to a line connecting the center of the resected tibial plateau and the center of the talar dome. Methods I and 2 caused significantly more valgus alignment than Method 3 (P<.0001). The postoperative weight-bearing ratio was in Method 1, 57.7%, in Method 2, 53.6% and 50.0% in Method 3. These results Suggest that Cutting the tibia perpendicular to the tibial shaft can cause valgus alignment in total knee arthroplasty for varus knees. Copyright 2003, Elsevier Science (USA). All rights reserved.
引用
收藏
页码:56 / 62
页数:7
相关论文
共 23 条
[1]   Lower limb alignment and foot angle are related to stance phase knee adduction in normal subjects: A critical analysis of the reliability of gait analysis data [J].
Andrews, M ;
Noyes, FR ;
Hewett, TE ;
Andriacchi, TP .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1996, 14 (02) :289-295
[2]  
[Anonymous], 1993, SURG KNEE 2
[3]  
CATES HE, 1993, CLIN ORTHOP RELAT R, V286, P32
[4]  
Evans P D, 1995, J Arthroplasty, V10, P43
[5]  
INSALL JN, 1985, CLIN ORTHOP RELAT R, V192, P13
[6]  
ISHII Y, 1995, CLIN ORTHOP RELAT R, P167
[7]   CORONAL ALIGNMENT AFTER TOTAL KNEE REPLACEMENT [J].
JEFFERY, RS ;
MORRIS, RW ;
DENHAM, RA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05) :709-714
[8]  
JINAG CC, 1989, CLIN ORTHOP RELAT R, V248, P50
[9]   POLYCENTRIC TOTAL KNEE ARTHROPLASTY - A 10-YEAR FOLLOW-UP-STUDY [J].
LEWALLEN, DG ;
BRYAN, RS ;
PETERSON, LFA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (08) :1211-1218
[10]  
Matsuda S, 1999, CLIN ORTHOP RELAT R, P249