A remote irrigation monitoring and control system (RIMCS) for continuous move systems. Part B: field testing and results

被引:28
作者
Chavez, Jose L. [1 ]
Pierce, Francis J. [2 ]
Elliott, Todd V. [2 ]
Evans, Robert G. [3 ]
Kim, Yunseop [3 ]
Iversen, William M. [3 ]
机构
[1] USDA ARS, Conservat & Prod Res Lab, Bushland, TX 79109 USA
[2] Washington State Univ, Ctr Precis Agr Syst, Prosser, WA 99350 USA
[3] USDA ARS, No Plains Agr Res Lab, Sidney, MT 59270 USA
关键词
Precision irrigation; Variable rate application; Wireless control; System evaluation;
D O I
10.1007/s11119-009-9110-8
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
Precision irrigation systems can have inherent errors that affect the accuracy of variable water application rates controllers, as well as affect the controllers' performance when evaluated on different continuous move irrigation systems configurations. The objective of this study was to assess the performance of a remote irrigation monitoring and control system (RIMCS) installed on two separate linear move (LM) irrigation systems. The RIMCS varies water application rates by pulsing nozzles controlled by solenoids connected via relays to a single board computer (SBC) with wireless Ethernet connection to a remote server. The system also monitors irrigation system flow, pressure, position and wireless field sensor networks. The system was installed on a LM irrigation system in Prosser, Washington, USA and on a LM in the Nesson Valley of North Dakota, USA. For the LM at Prosser, four pre-defined irrigation patterns were imposed and variable rates were applied as a percentage of the nozzle base application rate. Each nozzle was pulsed across the span length and along the LM travel direction. For the LM at the Nesson Valley, a quadratic pattern was imposed pulsing banks of nozzles along the LM travel direction. Standard catch can tests were performed and the system performance was evaluated by comparing measured catch can water depths with pre-determined target values. The RIMCS accuracy was found to be in the range of the LM uniform water depth application uniformity coefficients of 88-96%. The RIMCS was successfully transferred to another LM in North Dakota as indicated by the relatively low variable rate application errors of -8.8 +/- A 8.1% and -0.14 +/- A 6.7% for the two spans.
引用
收藏
页码:11 / 26
页数:16
相关论文
共 20 条
[1]  
ALKUFAISHI S, 2005, AGR ENG INT CI UNPUB, V7
[2]  
[Anonymous], 2007, ASAE Standards 2007, P1033
[3]  
BORDOVSKY JP, 2000, ANN REPORT 2000
[4]  
Camp C. R., 1998, Applied Engineering in Agriculture, V14, P23
[5]  
CHAVEZ JL, 2006, P 8 INT M PREC AGR A
[6]  
Christiansen JE, 1942, B U CALIFORNIA
[7]  
Evans R.G., 1996, P 3 INT C PREC AGR, DOI DOI 10.2134/1996.PRECISIONAGPROC3.C8
[8]  
FRAISSE CW, 1995, T ASAE, V38, P1371, DOI 10.13031/2013.27960
[9]  
HEERMANN DF, 1986, 862584 ASAE
[10]   Measurement accuracy analysis of sprinkler irrigation rainfall in relation to collector shape [J].
Hendawi, M ;
Molle, B ;
Folton, C ;
Granier, J .
JOURNAL OF IRRIGATION AND DRAINAGE ENGINEERING, 2005, 131 (05) :477-483