Image analysis measurements of roughness by texture and fractal analysis correlate with contact profilometry

被引:97
作者
Chappard, D [1 ]
Degasne, I
Huré, G
Legrand, E
Audran, M
Baslé, MF
机构
[1] CHU Angers, LHEA, F-49045 Angers, France
[2] Fac Med, F-49045 Angers, France
[3] CHU Angers, Serv Rhumatol, F-49033 Angers, France
[4] Clin Implantol, Paris, France
关键词
titanium; contact profilometry; image analysis; fractal geometry; roughness;
D O I
10.1016/S0142-9612(02)00524-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Surface properties of a biomaterial are important factors that govern in part its biocompatibility. Among them, surface roughness is now recognized as a very important factor for cell interactions. Surface roughness (Ra) is routinely measured by contact profilometry but other methods are presently usable. We compared two methods (contact profilometry and image analysis of scanning electron microscopic images SEM) on a series of 12 titanium test pieces. The texture analysis of SEM pictures was done by the heterogeneity and run-length methods. Fractal geometry was also used with the "skyscraper" and "blanket" methods providing respectively the D-SKY and D-BLANK fractal dimensions. The fractal dimension of the profilometric curve was also computed (D-MINK). Computer-simulated textures were used to evaluate the pertinence of the algorithms. A significant correlation was found between Ra and all the texture descriptors except heterogeneity. The correlation coefficient was dependent on the microscopic magnification. The fractal dimension of the curve was correlated with D-SKY and D-BLANK. Run-length, D-SKY and D-BLANK were highly correlated, independent of the magnification used, a finding related to the self-similarity of the images. Image texture analysis can be a useful alternative to profilometry with brittle or soft materials or with objects having a complex shape. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1399 / 1407
页数:9
相关论文
共 33 条
[1]   OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[2]  
Baslé MF, 1998, J BIOMED MATER RES, V40, P350, DOI 10.1002/(SICI)1097-4636(19980605)40:3<350::AID-JBM2>3.0.CO
[3]  
2-E
[4]  
BLACHER S, 1997, ACTA STEREOL, V16, P19
[5]  
Bowers K T, 1992, Int J Oral Maxillofac Implants, V7, P302
[6]   CHARACTERIZATION OF MAMMOGRAPHIC PARENCHYMAL PATTERN BY FRACTAL DIMENSION [J].
CALDWELL, CB ;
STAPLETON, SJ ;
HOLDSWORTH, DW ;
JONG, RA ;
WEISER, WJ ;
COOKE, G ;
YAFFE, MJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (02) :235-247
[7]  
Chappard D, 2002, MATH BIOSCI INTERACT, P171
[8]   Texture analysis of X-ray radiographs is a more reliable descriptor of bone loss than mineral content in a rat model of localized disuse induced by the Clostridium botulinum toxin [J].
Chappard, D ;
Chennebault, A ;
Moreau, M ;
Legrand, E ;
Audran, M ;
Basle, MF .
BONE, 2001, 28 (01) :72-79
[9]  
CHERMANT JL, 1983, ACTA STEREOL, V14, P509
[10]   USE OF GRAY VALUE DISTRIBUTION OF RUN LENGTHS FOR TEXTURE ANALYSIS [J].
CHU, A ;
SEHGAL, CM ;
GREENLEAF, JF .
PATTERN RECOGNITION LETTERS, 1990, 11 (06) :415-419