Three-dimensional load analysis of indentation stimulators

被引:7
作者
Bove, GM
Robichaud, DR
Grigg, P
机构
[1] Beth Israel Deaconess Med Ctr, Dept Anesthesia & Crit Care, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA 02215 USA
[3] Univ Massachusetts, Sch Med, Dept Physiol, Worcester, MA USA
关键词
von Frey hairs; filament stimulators; mechanical stimulation; allodynia; hyperalgesia; spring gauge;
D O I
10.1016/S0165-0270(02)00326-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The properties of three types of indentation stimulators: filament indenters, a spring gauge indenter, and an electromechanical stimulator, were evaluated by actuating each device against a 3-direction load cell. The on-axis loads produced by filament indenters were independent of the degree of buckling. The off-axis loads produced by a filament increased with the degree of buckling of the filament, and had magnitudes that were up to 25% of the on-axis load. Repeated applications of a filament produced loads whose magnitudes were very consistent. Offsetting the handle of a filament indenter altered the magnitude and the direction of the. off-axis load. Because these factors were poorly controlled in hand held trials, off-axis loads,were more variable in hand held trials. The spring gauge stimulator was, when hand held, very susceptible to creating large off-axis loads. When the off-axis loads were large, the spring gauge indicator underestimated the true on-axis loads. The electromechanical stimulator produced loads with a very high degree of consistency and could be arranged so that it produced very small off-axis loads. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:23 / 30
页数:8
相关论文
共 8 条
  • [1] THE REPEATABILITY OF TESTING WITH SEMMES-WEINSTEIN MONOFILAMENTS
    BELLKROTOSKI, J
    TOMANCIK, E
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1987, 12A (01): : 155 - 161
  • [2] Differences in the performance of commercially available 10-g monofilaments
    Booth, J
    Young, MJ
    [J]. DIABETES CARE, 2000, 23 (07) : 984 - 988
  • [3] Gere J. M., 1997, MECH MAT
  • [4] Tensile and compressive responses of nociceptors in rat hairy skin
    Khalsa, PS
    LaMotte, RH
    Grigg, P
    [J]. JOURNAL OF NEUROPHYSIOLOGY, 1997, 78 (01) : 492 - 505
  • [5] McGill M, 1998, DIABETIC MED, V15, P615, DOI 10.1002/(SICI)1096-9136(199807)15:7<615::AID-DIA641>3.3.CO
  • [6] 2-G
  • [7] Semmes J., 1960, Somatosensory changes after penetrating brain wounds in man
  • [8] WALLAS TR, 2002, SOC NEUR ABSTR, V27