Determination of trans fatty acids in hydrogenated vegetable oils by attenuated total reflection infrared spectroscopy:: Two limited collaborative studies

被引:12
作者
Adam, M
Chew, M
Wasserman, S
McCollum, A
McDonald, RE
Mossoba, MM
机构
[1] US FDA, Ctr Food Safety & Appl Nutr, Washington, DC 20204 USA
[2] US FDA, Natl Ctr Food Safety & Technol, Summit Argo, IL 60501 USA
[3] Lipton, Baltimore, MD 21229 USA
关键词
attenuated total reflection; collaborative study; infrared; trans fatty acid;
D O I
10.1007/s11746-998-0052-5
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
An attenuated total reflection infrared spectroscopy procedure was collaboratively studied among two sets of five laboratories for quantitating the total trans fatty acid levels in neat (without solvent) hydrogenated vegetable oils, measured as triacylglycerols in one study, and as fatty acid methyl ester derivatives in the other. Unlike the fatty acid methyl esters, the triacylglycerols required no derivatization but had to be melted prior to measurement. To obtain a symmetric absorption band at 966 cm(-1) on a horizontal background, the single-beam spectrum of the trans-containing fat was "ratioed" against that of a refined oil or a reference material that contained only cis double bonds. A single-bounce horizontal attenuated total reflection cell that requires 50 mu L of undiluted test samples was used for oils, melted fats, or their methyl esters. For fatty acid methyl esters, the reproducibility relative standard deviations were in the range of 0.9 to 18.46% for 39.08 to 3.41% trans, determined as methyl elaidate per total fatty acid methyl esters. For five pairs of triacylglycerol blind duplicates, the reproducibility and repeatability relative standard deviations were in the ranges of 1.62 to 18.97%, and 1.52 to 13.26%, respectively, for 39.12 to 1.95% trans, determined as trielaidin per total triacylglycerols. Six pairs of spiked triacylglycerol blind duplicates (quality assurance standards) exhibited high accuracy in the range of 0.53 to 40.69% trans and averaged a low bias of 1.3%. These statistical analysis results were compared to those collaboratively obtained by the recently adopted AOCS Cd14-95 and AOAC 994.34 Infrared Official Methods.
引用
收藏
页码:353 / 358
页数:6
相关论文
共 24 条
[1]   Determination of total trans fatty acids in foods: Comparison of capillary-column gas chromatography and single-bounce horizontal attenuated total reflection infrared spectroscopy [J].
Ali, LH ;
Angyal, G ;
Weaver, CM ;
Rader, JI ;
Mossoba, MM .
JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1996, 73 (12) :1699-1705
[2]   DETERMINATION OF TRANS ISOMERS IN GLC FRACTIONS OF UNSATURATED ESTERS [J].
ALLEN, RR .
LIPIDS, 1969, 4 (06) :627-&
[3]  
[Anonymous], 1989, J ASS OFF ANAL CHEM, V72, P694
[4]  
*AOCS, 1995, SMALL SER REP
[5]  
BELTON PS, 1988, LEBENSM WISS TECHNOL, V21, P153
[6]  
DRAPER NR, 1981, APPL REGRESSION ANAL, P33
[7]  
DUTTON HJ, 1974, J AM OIL CHEM SOC, V51, P406
[8]  
FIRESTONE D, 1965, J ASSOC OFF AGR CHEM, V48, P437
[9]  
FIRESTONE D, 1995, OFFICIAL METHODS REC
[10]  
FIRESTONE D, 1992, ADV LIPID METHODOLOG, P273