Detailed design of ex-vessel neutron yield monitor for ITER

被引:11
作者
Asai, K [1 ]
Iguchi, T
Watanabe, K
Kawarabayashi, J
Nishitani, T
Walker, CI
机构
[1] Nagoya Univ, Grad Sch Engn, Chikusa Ku, Nagoya, Aichi 4648603, Japan
[2] Japan Atom Energy Res Inst, Tokai, Ibaraki 3191195, Japan
[3] Max Planck Inst Plasma Phys, ITER Int Team, D-85748 Garching, Germany
关键词
D O I
10.1063/1.1779619
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Taking into consideration the latest design of the International Thermonuclear Experimental Reactor (ITER) main units, we have made the detailed design consideration for an ex-vessel neutron yield monitor to meet the ITER requirements. The monitoring system is constructed of four detector modules consisting of several U-235 fission chambers with different sensitivities and graphite (or beryllium) neutron moderator. We also selected possible spaces in the diagnostic ports to install them at appropriate distances and neutron shielding effects from the plasma. Through Monte Carlo neutron transport calculations, it has been confirmed that the present system can cover all the neutron yields encountered in the ITER experiments including the in situ calibrations with a time resolution around 200 mus without detector replacement over the whole ITER experiments. This system can also be calibrated with 10% of required accuracies in a realistic 50 h of accumulation time using a DT neutron generator. (C) 2004 American Institute of Physics.
引用
收藏
页码:3537 / 3539
页数:3
相关论文
共 8 条
[1]  
BARNES CW, 1997, REV SCI INSTRUM, V68, P1
[2]   A COUNTING-CAMPBELLING NEUTRON MEASUREMENT SYSTEM AND ITS EXPERIMENTAL RESULTS BY TEST REACTOR [J].
ENDO, Y ;
ITO, T ;
SEKI, E .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1982, 29 (01) :714-717
[3]   INSITU CALIBRATION OF TFTR NEUTRON DETECTORS [J].
HENDEL, HW ;
PALLADINO, RW ;
BARNES, CW ;
DIESSO, M ;
FELT, JS ;
JASSBY, DL ;
JOHNSON, LC ;
KU, LP ;
LIU, QP ;
MOTLEY, RW ;
MURPHY, HB ;
MURPHY, J ;
NIESCHMIDT, EB ;
ROBERTS, JA ;
SAITO, T ;
STRACHAN, JD ;
WASZAZAK, RJ ;
YOUNG, KM .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (07) :1900-1914
[4]  
*ITER COUNC, 2001, ITER FIN DES REP
[5]   IN-VESSEL CALIBRATION OF THE JET NEUTRON MONITORS USING A CF-252 NEUTRON SOURCE - DIFFICULTIES EXPERIENCED [J].
JARVIS, ON ;
SADLER, G ;
VANBELLE, P ;
ELEVANT, T .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (10) :3172-3174
[6]  
Judith F., 2000, LA13709M
[7]   Compact neutron generator for diagnostic applications [J].
Kaschuck, YA ;
Portnov, DV ;
Krasilnikov, AV ;
Amosov, VN ;
Siromukov, SV .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01) :1104-1106
[8]  
NISHITANI T, 1992, REV SCI INSTRUM, V63, P5270, DOI [10.1063/1.1143439, 10.1063/1.1143666]