CPR quality improvement during in-hospital cardiac arrest using a real-time audiovisual feedback system

被引:288
作者
Abella, Benjamin S. [1 ]
Edelson, Dana P.
Kim, Salem
Retzer, Elizabeth
Myklebust, Helge
Barry, Anne M.
O'Hearn, Nicholas
Hoek, Terry L. Vanden
Becker, Lance B.
机构
[1] Univ Penn, Dept Emergency Med, Ctr Resuscitat Sci, 3400 Spruce St,Ground Radvin, Philadelphia, PA 19104 USA
[2] Univ Chicago Hosp, Gen Internal Med Sect, Chicago, IL 60637 USA
[3] Univ Chicago Hosp, Sect Emergency Med, Chicago, IL 60637 USA
[4] Laerdal Med Corp, N-4002 Stavanger, Norway
[5] Univ Chicago Hosp, Dept Crit Care, Chicago, IL 60637 USA
关键词
heart arrest; cardiopulmonary resuscitation; chest compression; ventilation;
D O I
10.1016/j.resuscitation.2006.10.027
中图分类号
R4 [临床医学];
学科分类号
1002 [临床医学]; 100602 [中西医结合临床];
摘要
Background: Cardiopulmonary resuscitation (CPR) quality during actual cardiac arrest has been found to be deficient in several recent investigations. We hypothesized that real-time feedback during CPR would improve the performance of chest compressions and ventilations during in-hospital cardiac arrest. Methods: An investigational monitor/defibrillator with CPR-sensing and feedback capabilities was used during in-hospital cardiac arrests from December 2004 to December 2005. Chest compression and ventilation characteristics were recorded and quantified for the first 5 min of resuscitation and compared to a baseline cohort of arrest episodes without feedback, from December 2002 to April 2004. Results: Data from 55 resuscitation episodes in the baseline pre-intervention group were compared to 101 resuscitations in the feedback intervention group. There was a trend toward improvement in the mean values of CPR variables in the feedback group with a statistically significant. narrowing of CPR variable distributions including chest compression rate (104 +/- 18 to 100 +/- 13 min(-1); test of means, p = 0.16; test of variance, p = 0.003) and ventilation rate (20 +/- 10 to 18 +/- 8 min(-1); test of means, p = 0.12; test of variance, p = 0.04). There were no statistically significant differences between the groups in either return of spontaneous circulation or survival to hospital discharge. Conclusions: Real-time CPR-sensing and feedback technology modestly improved the quality of CPR during in-hospital cardiac arrest, and may serve as a useful adjunct for rescuers during resuscitation efforts. However, feedback specifics should be optimized for maximal. benefit and additional studies will be required to assess whether gains in CPR quality translate to improvements in survival. (c) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:54 / 61
页数:8
相关论文
共 26 条
[1]
Compression depth estimation for CPR quality assessment using DSP on accelerometer signals [J].
Aase, SO ;
Myklebust, H .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (03) :263-268
[2]
Quality of cardiopulmonary resuscitation during in-hospital cardiac arrest [J].
Abella, BS ;
Alvarado, JP ;
Myklebust, H ;
Edelson, DP ;
Barry, A ;
O'Hearn, N ;
Vanden Hoek, TL ;
Becker, LB .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (03) :305-310
[3]
Chest compression rates during cardiopulmonary resuscitation are suboptimal - A prospective study during in-hospital cardiac arrest [J].
Abella, BS ;
Sandbo, N ;
Vassilatos, P ;
Alvarado, JP ;
O'Hearn, N ;
Wigder, HN ;
Hoffman, P ;
Tynus, K ;
Vanden Hoek, TL ;
Becker, LB .
CIRCULATION, 2005, 111 (04) :428-434
[5]
Hyperventilation-induced hypotension during cardiopulmonary resuscitation [J].
Aufderheide, TP ;
Sigurdsson, G ;
Pirrallo, RG ;
Yannopoulos, D ;
McKnite, S ;
von Briesen, C ;
Sparks, CW ;
Conrad, CJ ;
Provo, TA ;
Lurie, KG .
CIRCULATION, 2004, 109 (16) :1960-1965
[6]
Improvement in timing and effectiveness of external cardiac compressions with a new non-invasive device: the CPR-Ezy [J].
Boyle, AJ ;
Wilson, AM ;
Connelly, K ;
McGuigan, L ;
Wilson, J ;
Whitbourn, R .
RESUSCITATION, 2002, 54 (01) :63-67
[7]
Better adherence to the guidelines during cardiopulmonary resuscitation through the provision of audio-prompts [J].
Chiang, WC ;
Chen, WJ ;
Chen, SY ;
Ko, PCI ;
Lin, CH ;
Tsai, MS ;
Chang, WT ;
Chen, SC ;
Tsan, CY ;
Ma, MHM .
RESUSCITATION, 2005, 64 (03) :297-301
[8]
Influence of cardiopulmonary resuscitation prior to defibrillation in patients with out-of-hospital ventricular fibrillation [J].
Cobb, LA ;
Fahrenbruch, CE ;
Walsh, TR ;
Copass, MK ;
Olsufka, M ;
Breskin, M ;
Hallstrom, AP .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 281 (13) :1182-1188
[9]
Effects of compression depth and pre-shock pauses predict defibrillation failure during cardiac arrest [J].
Edelson, Dana P. ;
Abella, Benjamin S. ;
Kramer-Johansen, Jo ;
Wik, Lars ;
Myklebust, Helge ;
Barry, Anne M. ;
Merchant, Raina M. ;
Vanden Hoek, Terry L. ;
Steen, Petter A. ;
Becker, Lance B. .
RESUSCITATION, 2006, 71 (02) :137-145
[10]
Effects of interrupting precordial compressions on the calculated probability of defibrillation success during out-of-hospital cardiac arrest [J].
Eftestol, T ;
Sunde, K ;
Steen, PA .
CIRCULATION, 2002, 105 (19) :2270-2273