High-energy total body irradiation as preparation for bone marrow transplantation in leukemia patients: Treatment technique and related complications

被引:28
作者
Bradley, J
Reft, C
Goldman, S
Rubin, C
Nachman, J
Larson, R
Hallahan, DE
机构
[1] Univ Chicago, Dept Radiat & Cellular Oncol, Chicago, IL 60637 USA
[2] Univ Chicago, Dept Pediat, Chicago, IL 60637 USA
[3] Univ Chicago, Sect Hematol & Oncol, Chicago, IL 60637 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1998年 / 40卷 / 02期
关键词
total-body irradiation (TBI); thermoluminescent detector (TLD); high-energy irradiation; pair production; backscatter;
D O I
10.1016/S0360-3016(97)00578-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Bone marrow transplantation with conditioning regimens that include total-body irradiation (TBI) is widely used in patients with acute lymphoblastic and acute myelocytic leukemias, The major causes of death in this population are relapse of leukemia, infection, and treatment related complications. Our purpose was to achieve a homogenous radiation dose distribution and to minimize the dose to the lungs, liver, and kidneys so that the incidence of organ injury was reduced, Methods and Materials: Dose to the bone marrow, midplane, and periphery was quantified by use of thermoluminescent detectors in a bone-equivalent tissue phantom, In an effort to reduce the risk of complications, we treated relapsed or refractory leukemia patients with TBI administered in fractionated, parallel opposed large fields with 24 MV photons, using tissue compensation and partial-transmission lung shielding, Tissue toxicities were then determined, Results: Dose quantitation in bone-equivalent and tissue-equivalent phantoms demonstrated that backscatter and pair production interactions adjacent to bone increased the bone marrow dose by 6 to 11%, At an SSD of 400 cm and at patient diameters of 20 to 40 cm, the percent inhomogeneity across the phantom with 24 MV photons was 0 to 0.3%, compared to 4 to 6% for 6 MV photons. End organ toxicities consisted of clinical interstitial pneumonitis in six patients, idiopathic interstitial pneumonitis in three patients, renal toxicity in seven patients, and veno-occlusive disease of the liver in one patient. Toxicities did not correlate with fractionation schedule. Conclusions: Total-body irradiation administered with 24 MV photons increases the dose deposition in bone marrow through pair production and backscatter interactions occurring in bone. Because percent depth dose increases with SSD, the 24 MV beam is more penetrating at a 400 cm distance than at 100 cm and dose homogeneity is improved with higher energies, Thus, the incidence of radiation-mediated injury to lung, liver, and kidney is reduced. This is an effective preparatory regimen for patients with high-risk leukemias requiring bone marrow transplantation. (C) 1998 Elsevier Science Inc.
引用
收藏
页码:391 / 396
页数:6
相关论文
共 27 条
[1]   BONE-MARROW TRANSPLANTATION FOR ACUTE LYMPHOBLASTIC-LEUKEMIA [J].
BARRETT, AJ ;
KENDRA, JR ;
LUCAS, CF ;
JOSS, DV ;
JOSHI, R ;
DESAI, M ;
JONES, KH ;
PHILLIPS, RH ;
ROGERS, TR ;
TABARA, Z ;
WILLIAMSON, S ;
HOBBS, JR .
BRITISH JOURNAL OF HAEMATOLOGY, 1982, 52 (02) :181-188
[2]  
BLUME KG, 1993, BLOOD, V81, P2187
[3]  
BLUME KG, 1987, BLOOD, V69, P1015
[4]  
BLUME KG, 1982, NEW ENGL J MED, V306, P610
[5]  
BLUME KG, 1987, BLOOD, V69, P1789
[6]   HIGH-DOSE ETOPOSIDE, CYCLOPHOSPHAMIDE, AND TOTAL-BODY IRRADIATION WITH ALLOGENEIC BONE-MARROW TRANSPLANTATION FOR PATIENTS WITH ACUTE MYELOID-LEUKEMIA IN UNTREATED FIRST RELAPSE - A STUDY BY THE NORTH-AMERICAN MARROW TRANSPLANT GROUP [J].
BROWN, RA ;
WOLFF, SN ;
FAY, JW ;
PINEIRO, L ;
COLLINS, RH ;
LYNCH, JP ;
STEVENS, D ;
GREER, J ;
HERZIG, RH ;
HERZIG, GP .
BLOOD, 1995, 85 (05) :1391-1395
[7]  
CHAMPLIN RE, 1982, BLOOD, V60, pA165
[8]   Toxicities of total-body irradiation for pediatric bone marrow transplantation [J].
Chou, RH ;
Wong, GB ;
Kramer, JH ;
Wara, DW ;
Matthay, KK ;
Crittenden, MR ;
Swift, PS ;
Cowan, MJ ;
Wara, WM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (04) :843-851
[9]  
DINSMORE R, 1983, BLOOD, V62, P381
[10]   RANDOMIZED COMPARISON OF CYCLOPHOSPHAMIDE TOTAL-BODY IRRADIATION VERSUS BUSULFAN CYCLOPHOSPHAMIDE CONDITIONING IN AUTOLOGOUS BONE-MARROW TRANSPLANTATION FOR ACUTE MYELOID-LEUKEMIA [J].
DUSENBERY, KE ;
DANIELS, KA ;
MCCLURE, JS ;
MCGLAVE, PB ;
RAMSAY, NKC ;
BLAZAR, BR ;
NEGLIA, JP ;
KERSEY, JH ;
WOODS, WG .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :119-128